User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Data storage
Plant data
13
184 | 351 CM110664en_07
13.5 Plant data
Plant data is process data from the operation of a customer plant, that is permanently saved from the time
of commissioning. Process data represents process variables in a building. The data is continuously
changed by the environment, automation station and, in the event of physical outputs, the operator. Most
process data is volatile. Few process data, such as adaptive control parameters and runtime totalization
counts, remains available following a restart or power failure of the automation station. Process data can
be archived as plant data.
13.6 Data transfer processes
Project data is transferred from the tools to the devices or other consumers online and offline via the
system interface. PX automation stations are configured offline and then the data is downloaded onto the
automation station. Desigo room automation stations (PXC3 and DXR2) can be engineered. DXR2
automation stations also have preloaded applications and only need to be configured.
Transfer operations
There are four transfer operations for data synchronization:
● Offline generation
● Online loading
● Online readback
● Offline import
Data transfer to PX automation stations
You can load a new program on a PX automation station while the old program is still running. The
operation of the automation station is not interrupted. Process values remain intact. If you load a firmware
on the automation station, you must restart the automation station.
Data transfer to Desigo room automation stations
If you load a new program on a Desigo room automation station, you must restart the automation station.
The operation of the automation station is interrupted. Process values do not remain intact. If you load a
firmware on the automation station, you must restart the automation station.
There are four loading units for Desigo room automation stations:
● Load program
● Load parameters (full download for DXR automation stations)
● Load configuration (settings on the automation station)
● Load firmware (programs, parameters and configuration are not lost)
Offline generation
Full code generation
Full code generation:
● Checks the overall application consistency (limits, identifiers)
● Converts the application into loadable units
● Generates the appropriate description data for configuration
You must compile the code to get the required performance. You cannot engineer a compiled program.
Delta generation
Delta generation (converts only the modifications):
● Improves performance
● Is faster than full code generation
Online loading
Full download
The full download transfers all loadable units into the automation station.
Delta download
The delta download: