User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Data storage
Data categories
13
CM110664en_07 181 | 351
13 Data storage
Large volumes of data are created in the Desigo system during engineering, commissioning and plant
operation. The data is processed, saved, and archived as needed in accordance with type, generation, and
meaning in the various system components.
13.1 Data categories
The application logic (control functions) and the required setting and configuration data are processed
during engineering and loaded in the corresponding system products, such as Desigo CC or an automation
station during commissioning.
This data is arranged according to two criteria:
● Data category
● Data ownership
Data categories: A common method of classifying data in building automation and
control systems
Data category Description Related terms
Program elements Software components which perform a predefined task
and have a known interface.
Function blocks, functions, program
blocks, compounds, solutions
Setting parameters Values that affect the program elements. Setpoints, default values, limit
values, address settings
Configuration parameters Data in the form of defined constants, or data that
influences the appearance or operability of the plant.
Description data, templates, profile,
metadata
Process data Physical process variables of the plant during operation.
History or saved process data are plant data.
Measured values, state variables,
calculated values
Data ownership
Data ownership is based on the practical allocation of data to its owner. The owner, usually an
organizational entity, a person, or a group of people, checks the data and is responsible for its scope and
content. Data ownership shows in which Desigo system product the data is located and which tools are
available for its management. Data ownership is divided in four groups.
The following table shows the four data ownership groups.
Data ownership Description Owner User
Program data Software of a Desigo system product with
basic data blocks.
Research & Development
(R&D) (HQ)
Project/Library engineer
Libraries Collection of predefined, specific, and
tested program elements.
Libraries can be copied and customized.
Library manager (HQ/RC) Project/Library engineer
Project data All data for the customer project or
customer plant.
Contractor
Project engineer
Plant operator
Plant data Data from the customer plant saved
permanently following commissioning.
Plant operator Customer
13.2 Program data
The executable software of a Desigo component is composed of programs. There are system and product
components.
System components
System components are: