User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Alarm management
Alarm routing over the network
9
160 | 351 CM110664en_07
Preconfigured alarm receivers
The preconfigured alarm receivers are entered in the notification class object:
● In the [DestList] for Desigo PX
● In the [RecpList] for Desigo room automation
Time response in the network
The routing of all alarm and acknowledgement ,messages between the alarm server and the alarm clients
takes place over the BACnet network using special BACnet services. These are:
● Confirmed Event Notification for all changes in the alarm state of an alarm-generating object
(TO_OFFNORMAL, TO_NORMAL, TO_FAULT), and for messages via local acknowledgements.
Direction: Direction: From alarm server to alarm client.
● AcknowledgeAlarm for the routing of acknowledgements (including reset) performed by the user on an
alarm client. Direction: From alarm client to alarm server.
The two services are referred to as Confirmed Services, that is, the receiving device always confirms the
receipt of a service by immediately returning a SimpleAck message. This tells the transmitting device that
its message has been received by the receiving device. If no SimpleAck message is received, the
transmitting devices tries to send the message again (up to three times).
An alarm is always issued by one (and only one) alarm server. Generally, however, there will be several
alarm clients on the network. To maintain consistency, all alarm clients must always display the same
alarm state. For this reason, all alarm-related functions must always be routed to all the alarm clients. The
procedure is the same for both temporary and pre-configured alarm receivers.
The following time-diagrams describe the communications via the network for the various alarm-related
events.
Change of alarm state
This procedure is carried out for every change in alarm state on an alarm server: TO_OFFNORMAL,
TO_FAULT und TO_NORMAL. The data record Confirmed Event Notification contains the following
information:
● BACnet address of the alarm server
● Object ID of the alarm-generating object
● Time stamp
● Alarm priority
● Initial and final state of the transmitted state transition (this is used to determine whether the state
transition is TO_OFFNORMAL, TO_FAULT or TO_NORMAL)
● Acknowledgement required [AckReq]: Does the notified state transition require acknowledgement or
not?
● Alarm text
● Other technical details
Based on this information, the alarm client can present the alarm in a comprehensible way; it may also read
additional information automatically from the alarm server, and if required, return any acknowledgement to
the correct address.
If a temporary alarm receiver does not confirm receipt with a SimpleAck message (via the Confirmed Event
Notification input), the alarm server will try three times more to transmit the alarm to the relevant alarm
receiver. The message for this alarm client will then be lost and its reference will be deleted from the
[RecpList] of the BACnet device object.
Alarm acknowledgement over the network
This process is performed for all acknowledgements made on an alarm client.