User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
Alarm management
Alarm routing over the network
9
CM110664en_07 159 | 351
Alarm receiver syntax:
Element Description
DeviceName Device name. In plain text so that the user can understand it.
Example: CC 01
DeviceIdentifier Device Identifier. Alternative syntax for the alarm receiver of a third-party manufacturer. If
the alarm receiver has a special address range or if DeviceName does not work.
Example: [13456]
RemoteAreaSiteName Remote area site name. In plain text so that the user can understand it.
Example: Chur
NetworkNumber Network number. Required with a third-party half router.
Example: [3]
9.7 Alarm routing over the network
Alarm server and alarm clients
Alarm servers are entities capable of producing an alarm. Alarm clients are entities capable of receiving an
alarm.
There are two types of alarm client: temporary alarm receivers and pre-configured alarm receivers. The
following concept for temporary alarm recipients is only valid for Desigo PX.
Temporary alarm receivers
Temporary alarm receivers are not defined at the engineering stage. They can be connected to or removed
from the network at any time during operation. If a temporary alarm receiver is connected to the network, it
will perform the following activities for every alarm server:
● The alarm recipient enters its address in the BACnet property recipient list [RecpList] of the BACnet
device object of the automation station, using the BACnet service AddListElement.
● Read information about all currently existing alarms, and all currently outstanding acknowledgements,
from the automation station (BACnet service GetEventInformation). This ensures that the alarm
receiver – irrespective of when it was connected – displays the current alarm status of the system.
After making these entries, the temporary alarm receiver, while connected, will receive all alarm messages
from the automation station in accordance with the routing mechanisms described below.
If an automation station cannot transfer an alarm message to a temporary alarm receiver (e.g., because it is
no longer connected to the network), the address of the receiver concerned will be removed from the
[RecpList]. All alarm messages destined for that receiver will then be deleted.
B=
A..Z
a..z
0..9
DeviceIdentifier
DeviceIdentifier
DeviceIdentifier
RemoteAreaSite
Not case-sensitive
Permanently
connected
alarm receiver
Alarm receiver with
PTP connection
and Desigo PX
half router
Alarm receiver with
PTP connection
and third-party
half router