User Manual
Table Of Contents
- 1 Cyber security disclaimer
- 2 Preconditions of this document
- 3 System overview
- 4 Desigo workflow, tools and programming
- 4.1 Coverage of the technical process
- 4.2 Coverage of the system
- 4.3 Main tasks
- 4.4 Tools for different roles
- 4.5 Working with libraries
- 4.6 Working in parallel and subcontracting
- 4.7 Workflow for primary systems
- 4.8 Workflow for room automation classic
- 4.9 Workflow for Desigo room automation
- 4.10 Desigo Configuration Module (DCM)
- 4.11 Desigo Xworks Plus (XWP)
- 4.12 Desigo Automation Building Tool (ABT)
- 4.13 Programming in D-MAP
- 5 Control concept
- 6 Technical view
- 7 Global objects and functions
- 8 Events and COV reporting
- 9 Alarm management
- 9.1 Alarm sources
- 9.2 Alarm example
- 9.3 Effects of BACnet properties on alarm response
- 9.4 Alarm response of the function blocks
- 9.5 Alarm functions
- 9.6 Alarm management by notification class
- 9.7 Alarm routing over the network
- 9.8 Alarm queuing
- 9.9 Common alarms
- 9.10 Alarm suppression
- 9.11 Alarm message texts
- 10 Calendars and schedulers
- 11 Trending
- 12 Reports
- 13 Data storage
- 14 Network architecture
- 15 Remote access
- 16 Management platform
- 17 Desigo Control Point
- 18 Automation stations
- 19 Logical I/O blocks
- 20 Room automation
- 21 Desigo Open
- 22 System configuration
- 22.1 Technical limits and limit values
- 22.2 Maximum number of elements in a network area
- 22.3 Desigo room automation system function group limits
- 22.4 Devices
- 22.4.1 PXC..D automation stations / system controllers
- 22.4.2 LonWorks system controllers
- 22.4.3 Automation stations with LonWorks integration
- 22.4.4 PX Open integration (PXC001.D/-E.D)
- 22.4.5 PX Open integration (PXC001.D/-E.D + PXA40-RS1)
- 22.4.6 PX Open integration (PXC001.D/-E.D + PXA40-RS2)
- 22.4.7 PX KNX integration (PXC001.D/-E.D)
- 22.4.8 TX Open integration (TXI1/2/2-S.OPEN)
- 22.4.9 Number of data points on Desigo room automation stations
- 22.4.10 Number of data points for PXC3
- 22.4.11 Number of data points for DXR1
- 22.4.12 Number of data points for DXR2
- 22.4.13 PXM20 operator unit
- 22.4.14 PXM10 operator unit
- 22.4.15 Desigo Control Point
- 22.4.16 PXG3.L and PXG3.M BACnet routers
- 22.4.17 SX OPC
- 22.4.18 Desigo CC
- 22.4.19 Desigo Insight
- 22.4.20 Desigo Xworks Plus (XWP)
- 22.4.21 Desigo Automation Building Tool (ABT)
- 22.5 Applications
- 23 Compatibility
- 23.1 Desigo version compatibility definition
- 23.2 Desigo system compatibility basics
- 23.2.1 Compatibility with BACnet standard
- 23.2.2 Compatibility with operating systems
- 23.2.3 Compatibility with SQL servers
- 23.2.4 Compatibility with Microsoft Office
- 23.2.5 Compatibility with web browsers
- 23.2.6 Compatibility with ABT Go
- 23.2.7 Compatibility with VMware (virtual infrastructure)
- 23.2.8 Compatibility of software/libraries on the same PC
- 23.2.9 Hardware and firmware compatibility
- 23.2.10 Backward compatibility
- 23.2.11 Engineering compatibility
- 23.2.12 Compatibility with Desigo Configuration Module (DCM)
- 23.2.13 Compatibility with Desigo PX / Desigo room automation
- 23.2.14 Compatibility with Desigo RX tool
- 23.2.15 Compatibility with TX-I/O
- 23.2.16 Compatibility with TX Open
- 23.3 Desigo Control Point
- 23.4 Upgrading from Desigo V6.2 Update (or Update 2) to V6.2 Update 3
- 23.5 Siemens WEoF clients
- 23.6 Migration compatibility
- 23.7 Hardware requirements of Desigo software products
- 24 Desigo PXC4 and PXC5
- 25 Compatibility of Desigo V6.2 Update 3 with PXC4 and PXC5
System overview
Management level
3
12 | 351 CM110664en_07
3.1 Management level
Operation and monitoring
The key functions at the management level are operation and monitoring of the plant, including:
● Graphics-based operation of the plant
● Cross-site alarm generation and alarm transfer
● Maintenance of a long-term log
● Storage and graphical display of trend data
● Graphics-based operation of time schedules
● Display, navigation and modification of data objects, which are displayed in a hierarchical tree structure
● Visual monitoring of the operation of primary plants (monitoring to reduce energy consumption and
wear and tear)
● Visual monitoring of the rooms (HVAC, lights and blinds)
● Reporting function including energy reports
● Centralized time control and calendar functions
● Event program: Triggering system reactions based on system events
What is operation and monitoring?
Operation and monitoring encompasses all the interaction between a user and the plant via the building
automation and control system.
Task Activity
Observing the operational status of the plant or
building
Reading current values of all process variables, data objects and parameter
settings
Receiving and acknowledging alarms
Overview of all pending alarms
Recording and analyzing trends
Observing the operational status of the building
automation and control system
Overview of failed automation stations and network interruptions
Signaling of anormal hardware or software states in an automation station or
in the associated field devices
Manipulating the operational status of the plant or
building
Modifying parameter settings (e.g., setpoints of control programs)
Setting values for physical outputs of automation stations
Modifying system and management objects, especially calendars and time
schedules
Devices for operation and monitoring
The following devices let you operate and monitor the system:
● Desigo CC management platform either locally and/or with web operation
● PXM touch panels and operating devices
Operation and monitoring types
There are four operation and monitoring types:
● Generic operation
● Limited (station-specific) generic operation
You can limit the generic view to one or more selected automation stations (including alarm display).
● Engineered (project-specific) operation
You can generate a project-specific view in the engineering phase.
● Limited (user-specific) operation in Desigo CC
Management platform
Desigo CC can be installed on one computer, with full server and client functionality, or on several separate
computers. Web Clients, Windows App (ClickOnce) Clients and installed Clients can be added.