User's Manual

Table Of Contents
c05_ikon.fm
Installation and Administration
Configure further BSIP Only to the system
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 81
5.18 Configure further BSIP Only to the system
1. Attach the second BSIP1 to a PoE port of the network switch of the DECT
Network or via a power injector to a standard port of the network switch.
It is assumed that the first Base Station is the synchronization master for
the Over-Air synchronization of the second Base Station.
2. Wait about 1 minute until the LED states at the BSIP Only change to
permanently green and red.
3. At the WBM of the BSIP1 IWU switch to configuration page "Dect-
Device".
4. To scan the newly attached second BSIP click on the button [Scan/Sync].
5. Confirm the message box by clicking on [OK].
The newly attached second BSIP1 should be found automatically and a
record will be appended for it in the table of DECT devices.
If the BSIP1 is not found please read the chapter 5.34, “Troubleshooting
/ FAQ” concerning possible reasons.
The BSIP1 Only has to be configured for usage within the HiPath Cordless IP
system by the following procedure:
6. Select the newly created entry for BSIP Only and change the contents of
the following fields:
Enabled (necessary)
Set to Enabled for usage within the HiPath Cordless IP system.
Name (necessary)
Descriptive name for the BSIP1. Change the preconfigured name of the
BSIP1 (e.g. to the name of the physical location it is destinated for). This
name is only used for the internal configuration of the BSIP1.