Configure BSIP1 for IWU mode
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 71
The BSIP1 is accessible via the factory default IP address 192.168.2.1 in
BSIP1 IWU mode. To access the BSIP1 IWU WBM you have to configure an
IP address in the network 192.168.2.0/255.255.255.0, e.g. 192.168.2.101 on
your Maintenance PC.
1. If the IP address 192.168.2.1 is used in your network, you first have to
directly connect the Maintenance PC and the BSIP1 via ethernet. This
may be done with a direct ethernet connection via the power injector or
via a separate ethernet switch where only the Maintenance PC and the
BSIP1 are connected.
2. Test via ping, if the BSIP1 is replying to the ping requests at ip address
(ping 192.168.2.1).
3. If not, check all cabling, switch settings, (e.g VLAN configuration).
4. Ensure that the configured local IP of the maintenance PC adress is up
(e.g ping 192.168.2.101).
5. Access the WBM (Web based management) at the following URL: http://
192.168.2.1
6. Log in to the WBM with the following (case-sensitive) credentials:
7. Username: Siemens, Password: 1q21q2
8. Press the [Login] button. The configuration page for the BSIP1 in BSIP1
Only mode appears.