User's Manual

Table Of Contents
c05_ikon.fm
Installation and Administration
WBM related issues
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 63
Resynchronisation
Important: If a BSIP loses synchronisation it tries to resync to the configured
synchronisation base station. This process can not start until the last call at
this base station is released and no other calls (at the belonging base station)
are active.
5.4 WBM related issues
5.4.1 Supported Web Browser
Supported Web Browsers are:
Mozilla Firefox Versions 2 (2.0.0.16 ... 2.0.0.18) and Version 3.0.x (3.01 ..
3.0.6) and
Microsoft Internet Explorer Version 6.x and Version 7.x
For details refer to chapter 5.35, “Configuration hints for Web Browser”.
5.4.2 General WBM issues
Don't use special characters inside the objects for WBM. Supported
characters are
0-9, a-z, A-Z, "-" "_". Other characters may prevent the system services
from running correctly.
Don't configure names for objects with more than 20 Characters.
Changing of IP addresses of BSIP Only - after changes have been
applied, a manual [Scan/Sync] has to be applied to show the new values
Configuration and firmware files MUST NOT include spaces in their
filenames
Do not use multiple WBM session to different BSIPs at a single browser
session. This may influence the behaviour of the WBM sessions.
5.4.3 Multiple WBM sessions
If you login onto the same WBM session on which another user is logged on,
you are informed about that by a message box.