User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
Diagnosis and Maintenance
c07.fm
Troubleshooting
A31003-C1010-S100-2-7620, 08/2010
174 HiPath Cordless IP, Service Manual
7.3.2 What Happens If ...
7.3.2.1 Synchronism Symbol on Handset Display:
–"Base n"
flashes
No synchronization to base station
1. Is the mobile telephone not logged on?
2. If the mobile telephone is logged on to multiple
systems, is it switched to the correct system? Is
automatic system selection activated?
Check the base station.
–"Base n"
continuously visible
but no action is
possible
Synchronization to base station
1. An error tone can be heard when the line key is
pressed.
Temporary overload status (all the base station
speech paths are busy).
Wait, and try again.
2. Handset was not able to complete the locations
request successfully (handset contact to the
system).
Workaround:
Repeat locations request by switching off the
handset and then switching it on again.