User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
Diagnosis and Maintenance
c07.fm
Testing the Radio Area
A31003-C1010-S100-2-7620, 08/2010
164 HiPath Cordless IP, Service Manual
emitted as soon as you cross the border zone of the radio area. (To activate
the range warning tone, use the "Tones" menu on the mobile telephone
display.)
7
WARNING
Areas in the corners of buildings or behind metal structures should be
carefully checked (check the RSSI values several times).
In these radio area border zones, the radio connection to the base station
may be lost in the case of the following values:
• The measuring sites with RSSI value < 40 (< -80 dBm) should be entered or
marked in the building/site plan.
Step 3
If you require more accurate values than those obtained in step 2, we
recommended that you use the Hicom Cordless Service tool (HCS-DECT).
7.2 Testing the Radio Area
7.2.1 Significance of Results Obtained
NOTE: Values recorded with a mobile telephone are not very precise and are
intended to provide a rough assessment only. In addition, different values may be
recorded on each mobile telephone even though the ambient conditions are
identical. If you require more accurate results, we recommended that you use the
Hicom Cordless Service tool (HCS-DECT)
The following figure shows a sample display of the measuring results for a
Gigaset mobile telephone when a call is in progress:
RSSI < 40 (< -80 dBm)
FRAQ < 95%