User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
c06.fm
Technical Data
Base Stations
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 159
Do not remove the Ex-battery pack without good reason as charge state
monitoring and the recharge function will not work properly if you do! After the Ex-
battery pack is removed and reinserted, it must be discharged and recharged as
for the initial startup!
7
CAUTION
Only use approved Ex battery packs . Ex authorisation is only valid and the
handset can only be operated if this battery pack is installed. Other battery
packs are strictly prohibited. If they are used, Ex protection is no longer
valid.
Accessories
6.3.2 PoE Injector
• An injector is needed when operating the DECT IP base station on the
mains,
• Single-port PoE injector in compliance with IEEE 802.3af Class 2
• Injector is included in the scope of features
• The PoE injector ships with startup information and notes on LED status
displays.
Example for a capacity of 850 mAh:
– Talktime Up to 12 hours
– Standby-time Up to 380 hours, approx. 16 days
– Charging time approx. 3,7 h
– Initial charging time at least 10 h
• Housing approx. 166,5 x 56,0 x 35,4 mm (L x W x H)
• Weight incl. battery pack approx. 180 g
• Charging unit for EU including plug-
in power supply unit
S30852-H1786-R101
• Charging unit for UK including plug-
in power supply unit
S30852-H1786-L101