User's Manual

Table Of Contents
c06.fm
Technical Data
Base Stations
A31003-C1010-S100-2-7620, 08/2010
HiPath Cordless IP, Service Manual 151
LED status displays on the base station
No settings need be made at the base station.
LED 1/LED 2 on the front of the base station provides the following
information:
Operating State LED 1 LED 2
LED status at booting sequence
No power on Base station off off
BSIP1 is booting the the Active partition red
flashing
red
flashing
BSIP1 is booting the the Fallback partition red
flashing
off
BSIP1 is booting the Active partition with factory
defaults
red
fast flashing
red
fast flashing
BSIP1 is booting the Fallback partition with
factory defaults
red
fast flashing
off
BSIP1 is booting kernel with Active partition off red
BSIP1 is booting kernel with Fallback partition red off
LED status at working process
BSIP1 not ready
Services not started or starting
orange orange
BSIP1 ready
No LAN link
red red
BSIP1 ready
No Connection to IWU
green red
BSIP1 ready
All DECT-frequencies blocked or all available
DECT channels occupied
red green
BSIP1 ready
Link unsynchronized (DECT/LAN), no active call
off green
Table 7 LED status displays on the base station