User's Manual
Table Of Contents
- Contents
- List of Tables
- List of Figures
- 1 Introduction and Important Notes
- 2 Overview
- 3 Planning a HiPath Cordless IP System
- 3.1 Planning According to Call Traffic Load
- 3.2 General
- 3.3 Propagation Conditions for Radio Traffic
- 3.4 Determining the Installation Site
- 3.5 Installing Base Stations
- 4 Putting Into Service
- 5 Installation and Administration
- 5.1 Terminology
- 5.2 Network Concept
- 5.3 Synchronisation over air concept
- 5.4 WBM related issues
- 5.5 Phone related issues
- 5.6 Partition concept of BSIP1
- 5.7 Factory reset of BSIP1
- 5.8 Release notes
- 5.9 Quick Start
- 5.10 Quick start overview
- 5.11 Prepare and connect hardware
- 5.12 Configure BSIP1 for IWU mode
- 5.13 Configuration of VoIP (Infrastructure) network
- 5.14 Configuration of DECT network
- 5.15 Configuration of users at the PBX
- 5.16 Configuration of users at the BSIP IWU
- 5.17 Start system services and register handsets
- 5.18 Configure further BSIP Only to the system
- 5.19 "Quick Start" Completion
- 5.20 Further steps
- 5.21 Configuration reference
- 5.22 WBM overview
- 5.23 Administration
- 5.24 "Network/Gateways" Configuration
- 5.25 "Group" Configuration
- 5.26 Users Configuration
- 5.27 Dect Configuration
- 5.27.1 Configuration Page "Dect - Device"
- 5.27.2 Configuration Page "Dect - Sync"
- 5.27.3 Configuration Page "Dect - ARI"
- 5.27.4 Configuration Page "Dect - About"
- 5.27.5 Configuration Page "Dect - Radio" (Advanced mode)
- 5.27.6 Configuration Page "Dect - Call" (Advanced mode)
- 5.27.7 Configuration Page "Dect - Debug" (Advanced mode)
- 5.27.8 General DECT configuration
- 5.28 Debugging Configuration
- 5.29 "Status" Configuration
- 5.30 "System" Configuration
- 5.31 Configuration Hints for PBXs
- 5.32 HiPath OpenOffice EE
- 5.33 HiPath OpenOffice ME
- 5.34 Troubleshooting / FAQ
- 5.35 Configuration hints for Web Browser
- 6 Technical Data
- 7 Diagnosis and Maintenance
- 8 Open Source Software used in the Product
- Index
Installation and Administration
c05_ikon.fm
Dect Configuration
A31003-C1010-S100-2-7620, 08/2010
116 HiPath Cordless IP, Service Manual
Cipher (only available in Siemens Admin mode)
By activating the ciphering feature, the communication between the handset
and the configured base station is encrypted.
Configure this setting for all base stations to the same value.
5.27.4 Configuration Page "Dect - About"
This configuration page is only for information purposes on the created DECT
configuration.
1. Click [Scan/Sync] to update all values.
The columns of the configuration page have the following meaning (only
display):
• Note: The columns "Enabled" and "Name" are repeated on all sub pages.
A description of these can be found in chapter 5.27.1, “Configuration
Page "Dect - Device"”.)
BasestationSerialNr."
Serial number of the Base Station as read with "Scan/Sync".
Version
Displays the version number of the Firmware of the DECT module including
version date as read from the Base Station with "Scan/Sync".
IpAddr Module
IP address of the BSIP1 Only , as read with "Scan".
IpAddr Server
IP address of the DECT Server IP (DECT network) read with "Scan/Sync".
Server Port Broad
IP port on which the BSIP IWU communicates with the BSIP Only as read
from the Base Station with "Scan/Sync".