User's Guide

Table Of Contents
hwc_appendixa.fm
HiPath Wireless Controllers physical description
HiPath Wireless Controller C2400
9034530-02,
March 2010
HiPath Wireless Controller, Access Points and Convergence Software V7.11, User Guide 489
The description of the LED states and switches is provided below:
Reset Switch – Reboots the system.
RUN LED – Indicates the CPU’s initialization has completed and the system
is ready to provide application level services.
ACT LED – Indicates the system’s software is in active running state.
WARNING/ERROR LEDs – Indicate a problem in the running state of the
system.
When any of the alarm LEDs is lit, the seven segment display provides
the corresponding code point for the error indication. When the system is
fully active and running, the console displays the letter A as seen in
Figure 32.
LCT Switch – The LCT button is used during the manufacturing process and
is inactive otherwise.
INT LED – Not used in the current release.
A.3.2 LED states and Seven Segment Display (SSD)
codes
Firmware initialization:
Active
LED
Warning
LED
Error
LED
SSD Codes Condition
Green 0 The processor has started and the
firmware has taken control.
Green 3 The Host Controller Card has failed to
download Bootloader from Flash.
Green 4 The system is checking firmware
consistency.
Green 5 The system is formatting memory.
Green 6 The system is initializing load device.
Note: If the SSD code is stuck at 6 for
more than a minute, it implies that the
Network Processor Card is installed in
wrong slot.
Green 9 The system is loading subsystem.
Green b The system is starting the operation
system. The system is active.