2.8.3. Average amount
The fraction of the old shot data that is kept for averaging purposes. A higher
value will give a smoother profile at the expense of a slower echo profile
response.
3. Diagnostics
3.1. Echo Profile
To request a profile via SIMATIC PDM:
Open the menu Device – Echo Profile Utilities. (See
Echo profile on page 46
for more
detail.)
To request a profile via the handheld programmer:
Navigate to Echo Profile (3.1.) and press RIGHT arrow. (See
Requesting an Echo
Profile on page 37
for more details.)
3.2. Fault Reset
Clears the following faults:
To clear a fault using the handheld programmer:
Enter the fault code number then press RIGHT arrow.
Values
0.0 to 1.0
Default: 0.75
Note: Selected icon is highlighted.
Fault Code
Description
S3 Device Lifetime Reminder 1 (Maintenance Required)
S4 Device Lifetime Reminder 2 (Maintenance Demanded)
S6 Sensor Lifetime Reminder 1 (Maintenance Required)
S7 Sensor Lifetime Reminder 2 (Maintenance Demanded)
S8 Device Service Reminder 1 (Maintenance Required)
S9 Device Service Reminder 2 (Maintenance Demanded)
S12 Internal Temperature High
S17 Calibration Schedule Reminder 1 (Maintenance Required)
S18 Calibration Schedule Reminder 2 (Maintenance Demanded)
measure
pan left/right - selected/highlighted
distance from flange face to target
algorithm selection (trueFirst echo)
TVT
curve
material
level
confidence
value
zoom in/out
exit
Echo Amplitude (dB)
pan up/down
distance from Low Calibration Point to vertical cross-hair
Measurement Range
(0 to 50 m for example purposes)
exit icon selected /
highlighted
exit icon,
deselected