User's Manual
Table Of Contents
- Safety Notes
 - FCC Conformity
 - CE Electromagnetic Compatibility (EMC) Conformity
 - Industry Canada
 - The Manual
 - Technical Support
 - SITRANS LR560 Overview
 - Specifications
 - Installation
 - Wiring
 - Local Operation
 - Operating via AMS Device Manager
- Functions in AMS Device Manager
 - Programming via AMS Device Manager
 - Adding a new device
 - Startup
 - Configuring a new device
 - Changing Block Modes
 - Configure/Setup Parameters
- Transducer Block Parameters
 - Level Transducer Block Parameters
- Operation (LTB)
 - Simulation (Input)
 - Setup (LTB)
 - General
 - Calibration
 - Rate
 - Signal Processing (LTB)
 - Range
 - Echo Select
 - Sampling
 - Echo Quality
 - Filtering
 - TVT Setup
 - TVT Shaper 1
 - TVT Shaper 2
 - TVT Shaper 3
 - Echo Profile Parameters (view only)
 - Maintenance & Diagnostics (LTB)
 - Sensor Lifetime
 - Service Schedule
 - Communication (LTB)
 - Communication:
 
 - Configure/Setup (Liquid Crystal Display Block-LCD)
 - Configure/Setup (Diagnostic Transducer Block-DIAG)
 - Configure/Setup (Resource Block - RESOURCE)
 - Device Diagnostics (Level Transducer Block - LTB)
 - Device Diagnostics (Level Control Device Block - LCD)
 - Device Diagnostics (Diagnostic Transducer Block - DIAG)
 - Device Diagnostics (Resource Block - RESOURCE)
 
 - Password Protection
 
 - AMS Menu Structure
 - Parameter Reference
- 1. Quick Start
 - 2. Setup
- 2.1. Identification
 - 2.2. Device
 - 2.3. Sensor
 - 2.4. Signal Processing
- 2.4.1. Near Range
 - 2.4.2. Far Range
 - 2.4.3. Minimum Sensor Value
 - 2.4.4. Maximum Sensor Value
 - 2.4.5. Echo Select
 - 2.4.6. Sampling
 - 2.4.7. Echo Quality
 - 2.4.8. TVT (Auto False Echo Suppression) Setup
 - 2.4.9. TVT Shaper
- 2.4.9.1. Shaper 1-9
 - 2.4.9.2. Shaper 10-18
 - 2.4.9.3. Shaper 19-27
 - 2.4.9.4. Shaper 28-36
 - 2.4.9.5. Shaper 37-45
 - 2.4.9.6. Shaper 46-54
 - 2.4.9.7. Shaper 55-63
 - 2.4.9.8. Shaper 64-72
 - 2.4.9.9. Shaper 73-81
 - 2.4.9.10. Shaper 82-90
 - 2.4.9.11. Shaper 91-99
 - 2.4.9.12. Shaper 100-108
 - 2.4.9.13. Shaper 109-117
 - 2.4.9.14. Shaper 118-120
 
 
 - 2.5. AIFB 1
 - 2.6. AIFB 2
 - 2.7. Measured Values
 - 2.8. Filtering
 
 - 3. Diagnostics
 - 4. Service
 - 5. Communication
 - 6. Security
 - 7. Language
 
 - Appendix A: Alphabetical Parameter List
 - Appendix B: Troubleshooting
 - Appendix C: Maintenance
 - Appendix D: Technical Reference
- Principles of Operation
 - Echo Processing
 - Measurement Range
 - Measurement Response
 - Damping
 - Loss of Echo (LOE)
 - Temperature derating curves
 
 - Appendix E: Communications
 - Appendix F: Firmware Revision History
 - Glossary
 - Index
 - LCD menu structure
 
Page 18 SITRANS LR560 (FF) – OPERATING INSTRUCTIONS  7ML1998KL01
mmmmm
Installation
Mounting location
Nozzle location
Beam angle
• Beam angle is the width of the cone 
where the energy density is half of 
the peak energy density
• Peak energy density is directly in 
front of and in line with the antenna.
• Signal is transmitted outside the 
beam angle; therefore false targets 
may be detected.
Emission cone
• Keep emission cone free of 
interference from ladders, pipes, 
I-beams or filling streams. 
• Avoid central locations on tall, 
narrow vessels.
• LR560 uses circular polarization. 
Rotation of device is not required to 
optimize signal.
Environment
• Provide easy access for 
viewing the display and 
programming via the 
handheld programmer.
• Provide an environment 
suitable to the ambient 
temperature rating.
• Use a sunshield if the 
instrument will be 
mounted in direct 
sunlight.
Notes: 
• Correct location is key to a successful application.
• Avoid reflective interference from vessel walls and obstructions by following the 
guidelines below.
Notes: 
• For details on avoiding false echoes, see 
Auto False Echo Suppression (2.4.8.1.) 
 on 
page 142.
emission 
cone
min. 1 m (39")
4°
ambient temperature 
–40 °C to +80 °C 
(–40 °F to +176 °F)
process temperature
–40 to +100 °C (–40 to +212 °F) or 
–40 to +200 °C (–40 to +392 °F) 
(version dependent)