User's Manual
Table Of Contents
- Safety Notes
- FCC Conformity
- CE Electromagnetic Compatibility (EMC) Conformity
- Industry Canada
- The Manual
- Technical Support
- SITRANS LR560 Overview
- Specifications
- Installation
- Wiring
- Local Operation
- Operating via AMS Device Manager
- Functions in AMS Device Manager
- Programming via AMS Device Manager
- Adding a new device
- Startup
- Configuring a new device
- Changing Block Modes
- Configure/Setup Parameters
- Transducer Block Parameters
- Level Transducer Block Parameters
- Operation (LTB)
- Simulation (Input)
- Setup (LTB)
- General
- Calibration
- Rate
- Signal Processing (LTB)
- Range
- Echo Select
- Sampling
- Echo Quality
- Filtering
- TVT Setup
- TVT Shaper 1
- TVT Shaper 2
- TVT Shaper 3
- Echo Profile Parameters (view only)
- Maintenance & Diagnostics (LTB)
- Sensor Lifetime
- Service Schedule
- Communication (LTB)
- Communication:
- Configure/Setup (Liquid Crystal Display Block-LCD)
- Configure/Setup (Diagnostic Transducer Block-DIAG)
- Configure/Setup (Resource Block - RESOURCE)
- Device Diagnostics (Level Transducer Block - LTB)
- Device Diagnostics (Level Control Device Block - LCD)
- Device Diagnostics (Diagnostic Transducer Block - DIAG)
- Device Diagnostics (Resource Block - RESOURCE)
- Password Protection
- AMS Menu Structure
- Parameter Reference
- 1. Quick Start
- 2. Setup
- 2.1. Identification
- 2.2. Device
- 2.3. Sensor
- 2.4. Signal Processing
- 2.4.1. Near Range
- 2.4.2. Far Range
- 2.4.3. Minimum Sensor Value
- 2.4.4. Maximum Sensor Value
- 2.4.5. Echo Select
- 2.4.6. Sampling
- 2.4.7. Echo Quality
- 2.4.8. TVT (Auto False Echo Suppression) Setup
- 2.4.9. TVT Shaper
- 2.4.9.1. Shaper 1-9
- 2.4.9.2. Shaper 10-18
- 2.4.9.3. Shaper 19-27
- 2.4.9.4. Shaper 28-36
- 2.4.9.5. Shaper 37-45
- 2.4.9.6. Shaper 46-54
- 2.4.9.7. Shaper 55-63
- 2.4.9.8. Shaper 64-72
- 2.4.9.9. Shaper 73-81
- 2.4.9.10. Shaper 82-90
- 2.4.9.11. Shaper 91-99
- 2.4.9.12. Shaper 100-108
- 2.4.9.13. Shaper 109-117
- 2.4.9.14. Shaper 118-120
- 2.5. AIFB 1
- 2.6. AIFB 2
- 2.7. Measured Values
- 2.8. Filtering
- 3. Diagnostics
- 4. Service
- 5. Communication
- 6. Security
- 7. Language
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Principles of Operation
- Echo Processing
- Measurement Range
- Measurement Response
- Damping
- Loss of Echo (LOE)
- Temperature derating curves
- Appendix E: Communications
- Appendix F: Firmware Revision History
- Glossary
- Index
- LCD menu structure
Page 102 SITRANS LR560 (FF) – INSTRUCTION MANUAL 7ML19985LY01
mmmmm
Parameters
2.4.8.4. Shaper Mode
Enables/disables TVT Shaper (2.4.9.).
2.4.9. TVT Shaper
Adjusts the TVT (Time Varying Threshold) at a specified range (breakpoint
on the TVT). This allows you to reshape the TVT to avoid unwanted echoes.
There are 120 breakpoints arranged in 14 groups.
To access TVT shaper via AMS Device Manager see
TVT Shaper 1
on
page 55.
To use TVT shaper via local operation:
a) Go to Shaper Mode (2.4.8.4.) and select option ON.
b) In TVT shaper, go to Shaper 1-9 (2.4.9.1.).
c) Open Shaper 1 and enter the TVT Offset value (between –50 and
+50 dB).
d) Go to the next Shaper point and repeat step (c) till all desired
breakpoint values have been entered.
2.4.9.1. Shaper 1-9
2.4.9.2. Shaper 10-18
2.4.9.3. Shaper 19-27
2.4.9.4. Shaper 28-36
2.4.9.5. Shaper 37-45
2.4.9.6. Shaper 46-54
2.4.9.7. Shaper 55-63
2.4.9.8. Shaper 64-72
2.4.9.9. Shaper 73-81
2.4.9.10. Shaper 82-90
2.4.9.11. Shaper 91-99
2.4.9.12. Shaper 100-108
2.4.9.13. Shaper 109-117
2.4.9.14. Shaper 118-120
Options
ON
*
OFF
Notes:
• Shaper Mode (2.4.8.4.) must be turned ON in order for TVT shaper
breakpoints to be transferred
• We recommend using AMS Device Manager to access this feature.
• Put LTB Block into OOS Mode before changing settings, then back
into AUTO mode to display TVT.
Values
Range: –50 to +50 dB
Default: 0