Page 38 SITRANS LR560 (mA/HART) – INSTRUCTION MANUAL 7ML19985KB01
mmmmm
SIMATIC PDM
To install a new EDD
• Go to www.siemens.com/LR560 > Support > Software Downloads to download the
most up-to-date EDD from the product page of our website.
• Save the files to your computer and extract the zipped file to an easily accessed
location.
• Launch SIMATIC PDM – Manage Device Catalog, browse to the unzipped EDD file
and select it.
Configuring a new device
1) Check that you have the most recent EDD, and if necessary update it (see
To install a
new EDD
above).
2) Launch SIMATIC Manager and create a new project for LR560.
3) Open the menu Device – Master Reset and click OK.
4) After the reset is complete, upload parameters to the PC/PG.
5) Configure the device via the Quick Start wizard.
Quick Start Wizard via SIMATIC PDM
The graphic Quick Start Wizard provides an easy step-by-step procedure that configures the
device for a simple application.
Please consult the operating instructions or online help for details on using SIMATIC PDM.
1) If you have not already done so, check that you have the most up-to-date Electronic
Device Description (EDD) for your instrument. (See
Configuring a new device
above.)
2) Launch SIMATIC Manager and create a new project for LR560. (Application Guides
for setting up HART devices with SIMATIC PDM can be downloaded from the
product page of our website at: www.siemens.com/sitransLR560
.)
Notes:
• Clicking on Cancel during an upload from device to SIMATIC PDM will result in some
parameters being updated.
• Application Guides for setting up HART devices with SIMATIC PDM can be
downloaded from the product page of our website at:
www.siemens.com/sitransLR560
.