User's Manual

Table Of Contents
7ML19985KB01 SITRANS LR560 (mA/HART) – INSTRUCTION MANUAL Page 19
mmmmm
Installation
Aimer Adjustment
3" flange 4 and 6" flange
1. For 4" and 6" Aimer: Loosen the set screws in the locking ring.
Holding the electronics enclosure firmly, loosen the Aimer locking ring using the
supplied C spanner, until the LR560 drops down slightly. The enclosure can then be
turned freely.
2. Direct SITRANS LR560 so the antenna is pointed at an angle perpendicular to the
material surface, if possible.
3. When the desired position is reached, re-tighten the locking ring using the C
spanner, and tighten set screws.
4. For the 3" Aimer flange, tapered split washers with pressure rated versions are
provided to keep nuts and bolts perpendicular to the flange surface.
Note: Aiming will assist in measuring material in the cone.
Aimer
Aiming is not
required for signal
optimization with
78 GHz frequency.
Aiming will assist
in measuring
material in the
cone.