User's Manual

Table Of Contents
7ML19985KB01 SITRANS LR560 (mA/HART) – INSTRUCTION MANUAL Page 17
mmmmm
Installation
Mounting location
Nozzle location
Beam angle
Beam angle is the width of
the cone where the energy
density is half of the peak
energy density.
The peak energy density is
directly in front of and in line
with the antenna.
There is a signal transmitted
outside the beam angle,
therefore false targets may
be detected.
Emission cone
Keep emission cone free of
interference from ladders,
pipes, I-beams or filling
streams.
Avoid central locations on
tall, narrow vessels.
LR560 uses circular polarization. Rotation of device is not required to optimize
signal.
Notes:
Correct location is key to a successful application.
Avoid reflective interference from vessel walls and obstructions by following the
guidelines below.
Notes:
For details on avoiding false
echoes, see
Shaper Mode (2.8.4.)
on page 126.
emission
cone
min. 1 m (39")