User's Manual
Table Of Contents
- Safety Notes
- FCC Conformity
- CE Electromagnetic Compatibility (EMC) Conformity
- Industry Canada
- The Manual
- Technical Support
- SITRANS LR560 Overview
- Specifications
- Installation
- Wiring
- Local operation
- Operating via SIMATIC PDM
- Operating via FDT (Field Device Tool)
- Operating via AMS Device Manager
- AMS Menu Structure
- Parameter Reference
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Appendix F: HART Communications
- Appendix G: Firmware Revision History
- Glossary
- Index
- LCD menu structure
7ML19985KB01 SITRANS LR560 (mA/HART) – INSTRUCTION MANUAL Page 17
mmmmm
Installation
Mounting location
Nozzle location
Beam angle
• Beam angle is the width of
the cone where the energy
density is half of the peak
energy density.
• The peak energy density is
directly in front of and in line
with the antenna.
• There is a signal transmitted
outside the beam angle,
therefore false targets may
be detected.
Emission cone
• Keep emission cone free of
interference from ladders,
pipes, I-beams or filling
streams.
• Avoid central locations on
tall, narrow vessels.
• LR560 uses circular polarization. Rotation of device is not required to optimize
signal.
Notes:
• Correct location is key to a successful application.
• Avoid reflective interference from vessel walls and obstructions by following the
guidelines below.
Notes:
• For details on avoiding false
echoes, see
Shaper Mode (2.8.4.)
on page 126.
emission
cone
min. 1 m (39")
4°