User's Manual
Table Of Contents
- Safety Notes
- FCC Conformity
- CE Electromagnetic Compatibility (EMC) Conformity
- Industry Canada
- The Manual
- Technical Support
- SITRANS LR560 Overview
- Specifications
- Installation
- Wiring
- Local operation
- Operating via SIMATIC PDM
- Operating via FDT (Field Device Tool)
- Operating via AMS Device Manager
- AMS Menu Structure
- Parameter Reference
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Appendix F: HART Communications
- Appendix G: Firmware Revision History
- Glossary
- Index
- LCD menu structure
Page 148 SITRANS LR560 (HART) – INSTRUCTION MANUAL SITRANS LR560 (HART) – INSTRUCTION MANUAL 7ML19985KB01
Appendix C: menu chart
LCD menu structure
1. WIZARDS
1.1 QUICK START WIZ
VESSEL
RESPONSE RATE
UNITS
OPERATION
LOW CALIB. PT.
HIGH CALIB. PT.
1.2 AFES WIZ
1.3 COPY PARAMETERS TO DISPLAY
1.4 COPY PARAMETERS FROM DISPLAY
1.5 COPY FIRMWARE TO DISPLAY
1.6 COPY FIRMWARE FROM DISPLAY
2. SETUP
2.1 DEVICE
2.1.1 LONG TAG
2.1.2 TAG
2.1.3 DESCRIPTOR
2.1.4 MESSAGE
2.1.5 INSTAL DATE
2.1.6 HARDWARE REV
2.1.7 FIRMWARE REV
2.1.8 LOADER REV
2.1.9 MENU TIMEOUT
2.1.10MANUF. DATE
2.2 SENSOR
2.2.1 UNITS
2.2.2SENSOR MODE
2.2.3DAMPING FILTER
2.2.4TEMP. UNITS
2.2.5UNIT
2.3 CALIBRATION
2.3.1 LOW CALIB. PT.
2.3.2HIGH CALIB. PT.
2.3.3SENSOR OFFSET
2.4 RATE
2.4.1 RESPONSE RATE
2.4.2FILL RATE/MIN
2.4.3EMPTY RATE/MIN
2.5 FAIL-SAFE
2.5.1 MAT. LEV
2.5.2 TIMER
2.5.3 LEVEL
2.6 ANALOG OUTPUT SCALE
2.6.1 CURRENT OUTPUT FUNCTION
2.6.24 MA SETPOINT
2.6.320 MA SETPOINT
2.6.4MIN MA LIMIT
2.6.5MAX MA LIMIT
2.6.6MA OUTPUT MODE
2.6.7MANUAL VALUE
2.6.8MA OUTPUT VALUE
2.7 SIGNAL PROCESSING
2.7.1 NEAR RANGE
2.7.2 FAR RANGE
2.7.3 ECHO SELECT
2.7.3.1 ALGORITHM
2.7.3.2 ECHO THRESHOLD
2.7.3.3 POSITION DETECT
2.7.3.4 CLEF RANGE
2.7.3.5 ECHO MARKER
2.7.4 SAMPLING
2.7.4.1 ECHO LOCK
2.7.4.2 UP SAMP.
2.7.4.3 DOWN SAMP.
2.7.4.4 ECHO LOCK WINDOW
2.7.5 FILTERING
2.7.5.1 NARROW ECHO FILTER
2.7.5.2 REFORM ECHO
2.7.5.3 AVG AMOUNT
2.7.6 ECHO QUALITY
2.7.6.1 CONFIDENCE
2.7.6.2 ECHO STRENGTH
2.8 TVT SETUP
2.8.1 AUTO ECHO SUPP
2.8.2 AUTO SUPP RANGE
2.8.3 HOVER LEVEL
2.8.4 SHAPER MODE
2.9 TVT SHAPER
2.9.1 BREAKPOINT 1-9
2.9.2 BREAKPOINT 10-18
2.9.3 BREAKPOINT 19-27
2.9.4 BREAKPOINT 28-36
2.9.5 BREAKPOINT 37-45
2.9.6 BREAKPOINT 46-54
2.9.7 BREAKPOINT 55-63
2.9.8 BREAKPOINT 64-72
2.9.9 BREAKPOINT 73-81
2.9.10 BREAKPOINT 82-90
2.9.11 BREAKPOINT 91-99
2.9.12 BREAKPOINT 100-108
2.9.13 BREAKPOINT 109-117
2.9.14 BREAKPOINT 118-120
2.10 MEASURED VALUES
2.10.1 MAIN OUTPUT
2.10.2 O/P NO LINEAR
2.10.3 O/P NO OFFSETS
Notes:
• In Navigation mode ARROW keys navigate the menu in the
direction of the arrow..
• See
See Parameter Reference
on page 76.
for detailed information
and instructions.