User's Manual

Table Of Contents
7ML19985KB01 SITRANS LR560 (mA/HART) – INSTRUCTION MANUAL Page 9
mmmmm
Specifications
Enclosure
construction 316L/1.4404 stainless steel
conduit entry M20x1.5, or ½" NPT
conduit entry connector M12 connector (shipped with M20 to M12 adaptor)
optional) or 7/8" connector (shipped with 1/2" NPT to 7/8"
adaptor)
ingress protection Type 4X/NEMA 4X, Type 6/NEMA 6, IP68
lid with window polycarbonate (window material)
Lens antenna material
construction 40 m version PEI
100 m version PEEK
Air Purge Connection
equipped with female 1/8" NPT fitting
Weight
3" stainless steel flange model 3.15 kg (6.94 lb)
Environmental
location indoor/ outdoor
altitude 5000 m (16 404 ft) max.
ambient temperature -40 to +80 °C (-40 to +176 °F)
relative humidity suitable for outdoor
Type 4, 4X/NEMA 4, 4X, Type 6/NEMA 6, IP68
enclosure (see note above)
installation category I
pollution degree 4
Process
temperature and pressure
1)
Note: Use appropriate conduit seals to maintain IP or NEMA rating.
Versions
stainless
steel flange
Aimer flange
0.5 bar max.
Aimer flange
3.0 bar max
40 m
–40 to +100 °C
(–40 to +212 °F)
–40 to +100 °C
(–40 to +212 °F)
–40 to +100 °C
(–40 to +212 °F)
100 m
–40 to +200 °C
(–40 to +392 °F)
–40 to +200 °C
(–40 to +392 °F)
–40 to +120 °C
(–40 to +248 °F)
1)
Maximum and minimum temperatures are dependent on the process connection, antenna and
O-ring materials. Use of the Easy Aimer limits maximum temperature.