Quick Start: local
Quick Start Wizard via the handheld programmer
1. Quick Start
a. Point the programmer at the display (from a maximum distance of 500 mm [1.6 ft.]),
then press RIGHT arrow to activate PROGRAM mode and open menu level 1.
b. Press RIGHT arrow twice to navigate to menu item 1.1 and open parameter
view.
c. Press RIGHT arrow to open Edit mode or DOWN arrow to accept default
values.
d. To change a setting, scroll to the desired item or key in a new value.
e. After modifying a value, press RIGHT arrow to accept it and press DOWN arrow
to move to the next item.
f. The Quick Start Wizard settings are inter-related and changes apply only after you
click on Yes in Apply? at the end of the Quick Start steps.
1.1. Application Type
1.2. Response Rate
Sets the reaction speed of the device to measurement changes in the target range.
Use a setting just faster than the maximum filling or emptying rate (whichever is
greater).
1.3. Units
Select the units for the Quick Start variables (high and low calibration point, and level,
distance, or space)
Notes:
The Quick Start Wizard settings are inter-related and changes apply only after you
click on Yes in Apply?at the end of the Quick Start steps.
Do not use the Quick Start wizard to modify individual parameters: see instead
Parameter Reference
on page 49 (perform customization for your application only
after the Quick Start has been completed).
Options
STEEL
Silo construction
CONCRETE
Default: STEEL
Options
SLOW
0.1 m/minute
MED
1.0 m/minute
FAST
10.0 m/minute
Default: FAST
Options
M, CM, MM, FT, IN
Default: M