User's Manual

Table Of Contents
Page 22 SITRANS LR260 (HART) – OPERATING INSTRUCTIONS A5E32337683
mmmmm
Wiring
1. Intrinsically Safe wiring
For power demands see
Startup Behavior
on page 105.
For wiring requirements: follow local regulations.
Approved dust-tight and water-tight conduit seals are required for outdoor
NEMA 4X / type 4X / NEMA 6, IP67, IP68 locations.
Refer to
Instructions specific to hazardous area installations
on page 25.
Recommended intrinsically safe barriers are listed under
Passive Shunt Diode
Barriers
on page 23 and
Active barriers (repeating barriers)
on page 23.
Note: Selecting a suitable PLC input module, power supply, or barrier requires
knowledge about Intrinsic Safety and the application. It is the responsibility of the
installer to ensure that the intrinsically safe installation complies with both the
apparatus approval requirements and the relevant national code of practice.
SITRANS LR260
Siemens Milltronics Process Instruments, Peterborough
7MLxxxx-xxxxx-xxxx-
Encl.: NEMA / TYPE 4X, 6, IP67, IP68
Amb.Temp.: 40°C to 80°C
Power Rating: 24 V
Max.,4-20mA
Nom., 30 V
Serial No: GYZ / S1034567
HART
Ui=30V
Ii = 120 mA
Pi = 0.8 W
Ci=15nF
Li = 0.1 mH
0518
0891
BOX 1
Assembled in Canada with domestic and imported parts
KCC-REM-S49
SITRANSLR
1/2 DII1GD, ,2D
Ex ia IIC T4 Ga
Ex ta IIIC T100°C Da
SIRA 11ATEX2348X
IECEx SIR 11.0153x
ARP0108 Ex ia IIC T4 Ga
WARNING: Use Cable Rated >100°C
ATENÇÃO - RISCO POTENCIAL DE CARGA ELETROSTÁTICA VEJA INSTRUÇÕES
- UTILIZAR CABOS ADEQUADOS PARA TEMPERATURAS >100 °C
Ex ia IIC T4 Ga
Ex ta IIIC T 100°C Da
DNV 12.0081 X
OCP 0017
The ATEX certificate listed on the nameplate
can be downloaded from the product page of our website at: www.siemens.com/LR260. Go
to Support > Approvals / Certificates.
The IECEx certificate listed on the nameplate can be viewed on the IECEx website. Go to:
http://iecex.iec.ch
and click on Ex Equipment Certificates of Conformity then enter the
certificate number IECEx SIR 11.0153X.
Device nameplate (ATEX/IECEX/INMETRO/C-TICK)
FM/CSA Intrinsically Safe connection drawing number A5E03745229 can be downloaded
from the product page of our website at: www.siemens.com/LR260. Go to Support >
Installation Drawings > Level Measurement > Continuous - Radar.
Device nameplate (FM/CSA)