User's Manual
Table Of Contents
- Table of Contents
- SITRANS LR260 Overview
- Specifications
- Installation
- Wiring
- Quick Start via local operation
- Operating via SIMATIC PDM
- Parameter Reference
- Pull-down menus via SIMATIC PDM
- Quick Start Wizard
- 1. Quick Start
- 2. Setup
- 2.1. Device
- 2.2. Input
- 2.2.1. Sensor Calibration (SENSOR CALIB.)
- 2.2.1.1. Antenna
- 2.2.1.2. Sensor Units
- 2.2.1.3. Low Calibration Pt. (LOW CALIB. PT.)
- 2.2.1.4. High Calibration Pt. (HIGH CALIB. PT.)
- 2.2.1.5. Limit Sensor Value
- 2.2.1.6. Unit (Level)
- 2.2.1.7. Low Level Point
- 2.2.1.8. High Level Point
- 2.2.1.9. Level Offset
- 2.2.1.10. Sensor Offset
- 2.2.1.11. Temperature Units (TEMP UNITS)
- 2.2.3. Echo Processing (ECHO PROC)
- 2.2.4. TVT (Auto False Echo Suppression) setup
- 2.2.5. TVT Shaper
- 2.2.6. Rate
- 2.2.7. Transducer Block Values (for diagnostic purposes)
- 2.2.1. Sensor Calibration (SENSOR CALIB.)
- 2.3. Output
- 2.4. Fail-safe
- 3. Diagnostics
- 3.1. Fault Reset
- 3.2. Echo Profile
- 3.3. Measured Values (MEAS. VALUES)
- 3.3.1. Min. Measured Value (MIN. MEAS. VALUE)
- 3.3.2. Max. Measured Value (MAX. MEAS. VALUE)
- 3.3.3. Minimum Output Value - AIFB1 (MIN. OUTPUT FB1)
- 3.3.4. Maximum Output Value - AIFB1 (MAX. OUTPUT FB1)
- 3.3.5. Minimum Output Value - AIFB2 (MIN. OUTPUT FB2)
- 3.3.6. Maximum Output Value - AIFB2 (MAX. OUTPUT FB2)
- 3.3.7. Minimum Internal Temperature (MIN. INTERN. TEMP)
- 3.3.8. Maximum Internal Temperature (MAX. INTERN. TEMP)
- 3.4. Remaining Device Lifetime (REMAIN. DEV. LIFE)
- 3.4.1. Total Device Operating Time (TOTAL OP. TIME)
- 3.4.2. Remaining Device Lifetime (REMAIN LIFETIME)
- 3.4.3. Maintenance Required Limit (MAINT REQ LIMIT)
- 3.4.4. Maintenance Demanded Limit (MAINT DEM LIMIT)
- 3.4.5. Maintenance Alert Activation (ALERT ACTIVATION)
- 3.4.6. Total Expected Device Life (TOTAL EXP. LIFE)
- 3.4.7. Maintenance Status (MAINT STAT)
- 3.4.8. Acknowledge Status (ACK STATUS)
- 3.4.9. Acknowledge (ACK)
- 3.5. Remaining Sensor Lifetime (REMAIN SENS. LIFE)
- 3.5.1. Total Sensor Operating Time (SENS OP. TIME)
- 3.5.2. Remaining Sensor Lifetime (REMAIN LIFETIME)
- 3.5.3. Maintenance Required Limit (MAINT REQ LIMIT)
- 3.5.4. Maintenance Demanded Limit (MAINT. DEM. LIMIT)
- 3.5.5. Maintenance Alert Activation (ALERT ACTIVATION)
- 3.5.6. Total Expected Sensor Life (TOTAL EXP. LIFE)
- 3.5.7. Maintenance Status (MAINT STAT)
- 3.5.8. Acknowledge Status (ACK STATUS)
- 3.5.9. Acknowledge (ACK)
- 3.6. Condensed Status Setup (COND. STAT. SETUP)
- 3.7. Condensed Status
- 4. Service
- 4.1. Device Reset
- 4.2. LCD Fast Mode
- 4.3. LCD Contrast
- 4.4. PROFIBUS Ident Number (PROFIBUS IDENT)
- 4.5. Powered Hours
- 4.6. Power-on Resets
- 4.17. Service Interval
- 4.17.1. Time Last Serviced (TIME LAST SERV)
- 4.17.2. Remaining Lifetime (REMAIN LIFETIME)
- 4.17.3. Maintenance Required Limit (MAINT REQ LIMIT)
- 4.17.4. Maintenance Demanded Limit (MAINT DEM. LIMIT)
- 4.17.5. Alert Activation
- 4.17.6. Service Interval
- 4.17.7. Maintenance Status (MAINT STAT)
- 4.17.8. Acknowledge Status (ACK STATUS)
- 4.17.9. Acknowledge (ACK)
- 4.18. Calibration Interval (CALIB INTERVAL)
- 4.18.1. Time Last Calibrated (TIME LAST CAL.)
- 4.18.2. Remaining Lifetime (REMAIN LIFETIME)
- 4.18.3. Maintenance Required Limit (MAINT REQ LIMIT)
- 4.18.4. Maintenance Demanded Limit (MAINT DEM LIMIT)
- 4.18.5. Alert Activation
- 4.18.6. Total Calibration Interval (TOTAL CALIB. INTRV)
- 4.18.7. Maintenance Status (MAINT STAT)
- 4.18.8. Acknowledge Status (ACK STAT)
- 4.18.9. Acknowledge (ACK)
- 5. Communication
- 6. Security
- 7. Language
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Appendix E: Application Example
- Appendix F: PROFIBUS PA Profile Structure
- Appendix G: Communications via PROFIBUS PA
- Appendix H: Firmware Revision History
- Glossary
- Index
- LCD menu structure
A5E32337685 SITRANS LR260(PROFIBUS PA) ā OPERATING INSTRUCTIONS Page 91
mmmmm
A: Parameter List
Appendix A: Alphabetical Parameter
List
Note: Maintenance Parameters are not listed below. See
Remaining Device Lifetime
(REMAIN. DEV. LIFE) (3.4.) on page 74
,
Remaining Sensor Lifetime (REMAIN SENS. LIFE)
(3.5.) on page 77
,
Service Interval (4.17.) on page 85
, and
Calibration Interval (CALIB
INTERVAL) (4.18.) on page 87
for those parameters.
Parameter Name (Parameter Number) Page Number
Algorithm (2.2.3.1.1.) 56
Auto False Echo Suppression (AUTO ECHO SUPP) (2.2.4.3.) 62
Auto Suppression Range (AUTO SUPP RANGE) (2.2.4.4.) 63
Echo Confidence (2.2.3.6.1.) 61
Device Address (5.1.) 88
Device Reset (4.1.) 84
Echo Lock (2.2.3.2.1.) 58
Echo Marker (2.2.3.1.4.) 57
Echo Profile (3.2.) 72
Echo Threshold (2.2.3.1.2.) 57
Empty rate (EMPTY RATE/MIN) (2.2.6.3.) 66
Fail-safe Mode FB1 (FS MODE FB1) (2.4.2.) 71
Fail-safe Mode FB2 (FS MODE FB2) (2.4.4.) 71
Fail-safe Value FB1 (FS VALUE FB1) (2.4.3.) 71
Fail-safe Value FB2 (FS VALUE FB2) (2.4.5.) 71
Far Range (2.2.3.5.2.) 60
Fill Rate (FILL RATE/MIN) (2.2.6.2.) 65
Filter Time Constant (FILTER TIME CONST) (2.3.1.4.) 67
Firmware Revision (FIRMWARE REV.) (2.1.4.) 54
Hardware Revision (HARDWARE REV.) (2.1.6.) 54
High Calibration Pt. (HIGH CALIB. PT.) (2.2.1.4.) 55
Language (7.) 89
LCD Contrast (4.3.) 85
LCD Fast Mode (4.2.) 84
Level Offset (2.2.1.9.) 55
Loader Revision (LOADER REV.) (2.1.5.) 54
LOE Timer (2.4.1.) 70
Low Calibration Pt. (LOW CALIB. PT.) (2.2.1.3.) 55
Maximum Internal Temperature (MAX. INTERN. TEMP) (3.3.8.) 73
Minimum Internal Temperature (MIN. INTERN. TEMP) (3.3.7.) 73
Narrow Echo Filter (NARROW ECHO FIL.) (2.2.3.3.2.) 59