User's Manual

Table Of Contents
Page 54 SITRANS LR260 (PROFIBUS PA) – OPERATING INSTRUCTIONS A5E32337685
mmmmm
Parameters
2. Setup
2.1. Device
2.1.1. Tag
Text that can be used in any way. A recommended use is as a unique label for
a field device in a plant. Limited to 32 ASCII characters. Read only on device,
Read/Write using SIMATIC PDM.
2.1.2. Description
Text that can be used in any way. Limited to 32 ASCII characters. No specific
recommended use. Read only on device, Read/Write using SIMATIC PDM.
2.1.3. Message
Text that can be used in any way. Limited to 32 ASCII characters. No specific
recommended use. Read only on device, Read/Write using SIMATIC PDM.
2.1.4. Firmware Revision (FIRMWARE REV.)
Corresponds to the software or firmware that is embedded in the Field Device.
Read only.
2.1.5. Loader Revision (LOADER REV.)
Corresponds to the software used to update the Field Device. Read only.
2.1.6. Hardware Revision (HARDWARE REV.)
Corresponds to the electronics hardware of the Field Device. Read only.
2.2. Input
2.2.1. Sensor Calibration (SENSOR CALIB.)
2.2.1.1. Antenna
Displays antenna type.
2.2.1.2. Sensor Units
Sets engineering units to be used by the sensor for measurement.
Notes:
See
Programming via the handheld programmer
on page 30 or
Operating via
SIMATIC PDM
on page 37 for instructions.
Default settings in the parameter tables are indicated with an asterisk (*) unless
explicitly stated.
Values shown in the following tables can be entered via the handheld programmer.
Values
(view only)
No Horn, Horn 2, Horn 3, Horn 4
Default is set by factory depending on horn size.
Values
M, CM, MM, FT, IN
Default: m