User's Manual
Table Of Contents
- Table of Contents
- SITRANS LR250 Overview
- Specifications
- Installation
- Wiring
- Operating via the handheld programmer
- Operating via SIMATIC PDM
- Functions in SIMATIC PDM
- Quick Start Wizard via SIMATIC PDM
- Changing parameter settings using SIMATIC PDM
- Parameters accessed via pull-down menus
- Operating via AMS Device Manager
- Functions in AMS Device Manager
- Features of AMS Device Manager
- Device Description (DD)
- Configuring a new device
- Startup
- Pull-down menu access
- Device configuration
- Quick Start Wizard via AMS Device Manager
- Maintenance and Diagnostics
- Remaining Device Lifetime [see Remaining Device Lifetime (4.2.) on page 99]
- Remaining Sensor Lifetime [see Remaining Sensor Lifetime (4.3.) on page 102]
- Service Schedule [see Service Schedule (4.4.) on page 105]
- Calibration Schedule [see Calibration Schedule (4.5.) on page 108]
- Electronic Temperature
- Wear (see Wear on page 56)
- Communication
- Security
- Device Diagnostics
- AMS Menu Structure
- Functions in AMS Device Manager
- Parameter Reference
- 1. Quick Start
- 2. Setup
- 3. Diagnostics
- 4. Service
- 5. Communication
- 6. Security
- 7. Language
- Appendix A: Alphabetical Parameter List
- Appendix B: Troubleshooting
- Appendix C: Maintenance
- Appendix D: Technical Reference
- Principles of Operation
- Echo Processing
- Analog Output
- Maximum Process Temperature Chart
- Process Pressure/Temperature derating curves
- Loop power
- Appendix E: Application Examples
- Appendix F: HART Communications
- Appendix G: ATEX Certificates
- Appendix H: Firmware Revision History
- Glossary
- Index
- LCD menu structure
Page 60 SITRANS LR250 (HART) – INSTRUCTION MANUAL 7ML19985JE03
mmmmm
AMS Device Manger
Operating via AMS Device Manager
AMS Device Manager is a software package used to commission and maintain SITRANS
LR250 and other process devices. Please consult the operating instructions or online help for
details on using AMS Device Manager. (You can find more information at
http://www.emersonprocess.com/AMS
/.) Application Guides for setting up Siemens HART
devices with AMS Device Manager are available on our website at:
www.siemens.com/processautomation.
Functions in AMS Device Manager
AMS Device Manager monitors the process values, alarms and status signals of the device. It
allows you to display, compare, adjust, verify, and simulate process device data
Parameters organized into three main function groups allow you to configure and monitor
the device:
• Configure/Setup
• Device Diagnostics (read only)
• Process Variables (read only)
See
AMS Menu Structure
on page 73 for a chart
1)
and
Changing parameter settings
using AMS Device Manager
on page 65 for more details.
Features of AMS Device Manager
The graphic interface in SITRANS LR250 makes monitoring and adjustments easy.
Note: While the device is in PROGRAM mode the output remains fixed and does not
respond to changes in the device.
1)
The menu structure for AMS Device Manager is almost identical to that for the LCD.
Feature page Function
Quick Start 63 Device configuration for simple applications
Echo Profile 69 Echo profile viewing
TVT 68 Screen out false echoes
Linearization 64 Volume measurement in an irregular vessel
Process Variables 71 Monitor process variables and level trend
Security 70
Protect security and communication parameters
from modification by the maintenance user