User's Manual

Table Of Contents
7ML19985JE03 SITRANS LR250 (HART) – INSTRUCTION MANUAL Page 9
mmmmm
Specifications
Antenna:
horn standard 1.5" (40 mm), 2" (50 mm), 3" (80 mm), and
4" (100 mm) horn, optional 100 mm (4") horn extension
materials 316L stainless steel with PTFE emitter
optional Alloy N06022/2.4602 (C-22) with PTFE emitter
Enclosure
construction aluminum, polyester powder-coated
conduit entry 2 x M20x1.5, or 2 x ½" NPT
ingress protection Type 4X/NEMA 4X, Type 6/NEMA 6, IP 67, IP68 (see
note below)
Weight (excluding extensions)
1.5" threaded connection with 1.5" horn antenna approx. 5.1kg
(11.2 lb)
2" threaded connection with 2" horn antenna approx. 5.5 kg
(12.1 lb)
DN 50/PN 16 or 2" 150 lb flat-face flange with 2" horn antenna approx. 8 kg
(17.6 lb)
DN 100/PN 40 or 4" ASME 300 lb flat-face flange with 4" horn antennaapprox.
17.4 kg (38.3 lb)
DN 50/PN 16 raised-face flange with 2" horn antenna approx. 6 kg
(13.2 lb)
DN 100/PN 40 raised-face flange with 4" horn antenna approx.
11.3 kg (24.9 lb)
Environmental
location indoor/ outdoor
altitude 5000 m (16,404 ft) max.
ambient temperature 40 to +80 °C (40 to +176 °F)
relative humidity suitable for outdoor
Type 4X/NEMA 4X, Type 6/NEMA 6, IP67, IP68
enclosure (see note above)
installation category I
pollution degree 4
Notes:
Check
Approvals
on page 10, for the specific configuration you are about to use or
install.
Use appropriate conduit seals to maintain IP or NEMA rating.