Appendix A: Technical reference
A.2 Echo processing
SITRANS LR250 (FOUNDATION FIELDBUS)
234 Operating Instructions, 01/2014, A5E32221411-AB
A.2.3
CLEF Range
CLEF Range (2.5.7.4.)
is referenced from Low Calibration Point (process empty level). When the
Hybrid
algorithm is selected in
Position Detect (2.5.7.2.)
, the CLEF algorithm will be applied up
to the limit of CLEF Range. Above this limit the Center algorithm will be applied.
①
CLEF Range
②
(Center algorithm applied)
③
High Calibration Point (process full level)
④
Sensor reference point
⑤
Low Calibration Point (process empty level)