Temperature De-rating
Note:
Note:Note:
Note: UHMW-PE is limited to a maximum continuous service temperature of 80°C /
176°F.
Process temperature in degrees Celsius at IQ 300 flange.
ambient temperature in degrees Celsius at enclosure
e.g. If the IQ 300 is operating in an ambient temperature of 60 °C, then
the maximum process temperature allowable at the flange is 100 °C.