User's Manual
Table Of Contents
- Table of Contents
- General Information
- Specifications
- Installation
- Location
- Dimensions: IQ Radar 300 with Rod Antenna
- Dimensions: Threaded Rod
- Dimensions: Horn
- Mounting
- Rod Assembly
- Mounting: Rod Assembly
- Mounting: Manhole Covers
- Mounting: Horn Antennas
- Mounting: Waveguide Antenna
- Mounting: Stillpipe or Sidepipe
- Mounting: Horn with Waveguide Extensions
- Mounting: Sanitary Mounting
- Mounting: Location
- Interconnection
- Start Up
- Operation(
- Application Examples
- Parameter Descriptions
- _
- _
- Quick Start Parameters (P001 to P007)
- Volume Parameters (P050 to P053)
- Display and Reading Parameters (P060 to P063)
- Fail-Safe Parameters (P070 to P072)
- mA Parameters (P200 to P219)
- Independent mA Setpoints Parameters (P210 and P211)
- Profile Record Parameters (P330 to P337)
- Auto Record ON and OFF Setpoint Parameters (P334 to P337)
- Installation Records Parameter
- Range Calibration Parameters
- Rate Parameters
- Measurement Verification Parameters
- Communication Parameters
- Echo Processing Parameters
- Algorithm Parameters
- TVT Adjustment Parameters
- P837 Auto Near TVT
- Test Parameters
- _
- Communications: Modbus Register Map
- Communications: Data Types
- Error Handling
- Troubleshooting
- Maintenance(
- Appendix I
- Appendix II
- Appendix III
- Appendix IV
- Appendix V
PL-611 IQ Radar 300 Page 11
Specifications
Specifications
Specifications
Specifications
Specifications
Milltronics makes every attempt to ensure the accuracy of these specifications but
reserves the right to change them at any time. Contact your Milltronics representative
for the most recent specifications.
IQ Radar 300
Power:
• 100/115/200/230 ±15% V ac
1
, 50/60 Hz, 15 VA
Fuse:
• FU1, 2AG type, slow blow, .25 A, 250V
Interface:
• analog output: optically-isolated 0/4-20 mA into 750 Ω max, 0.02
mA resolution
• Dolphin/RS-485 link: refer to Dolphin Plus product specification
• programmer link: infrared receiver (refer to Programmer
specification on page 13)
• display (local): backlit, alphanumeric, and multi-graphic liquid
crystal for readout and entry
Performance:
• frequency: 5.8 GHz (U.S.A. 6.3 GHz)
• accuracy at 20° C: better than ±0.3% of range from 1 to 15m
• temperature drift: <±0.5% of range from –40 to 60° C (-40 to 392° F)
• measuring range: 0.4m to 15m
• repeatability: ± 10mm
• fail-safe: mA programmable high, low or hold upon LOE
condition
Mechanical:
Process Connections (Please refer to Appendix IV) for pressure/temperature limitations.)
• flat faced flanges: 316 stainless steel, 2”, 3”, 4”, 50mm, 80mm,
100mm. Bolt hole pattern to ANSI and DIN
types.
• threaded connection: 316 stainless steel, 1-1/2” or 2”, NPT, BSP
• sanitary connection: 316 stainless steel, 2”, 3”, or 4” tri-clamp
1 Factory set – see device nameplate.