User's Manual

Table Of Contents
Page 86 IQ Radar 300 PL-611
Communications
Communications
Communications
Communications
value
1
= value / 256
value
2
= remainder of value
1
value
3
= value
2
x 256
yy = value
3
128
It may simplify Parameter to notice:
xx = (most significant byte of value) 128
yy = (least significant byte of value) 128
Text Messages
If a device parameter returns a text message, that message is converted to an integer
and is then provided in the register. The numbers are shown in the following table:
Number Text Message as displayed on LCD
22222 Invalid value
30000 Off
30001 On
30002
30003
(parameter does not exist)
30004 Err
30005 Err1
30006 Open
30007 Short
30008 Pass
30009 Fail
30010 Hold
30011 Lo
30012 Hi
30013 De
30014 En
30015
(parameter has not been set)
-32768 Value is less than -20,000
32767 Value is greater than 20,000