User's Manual
Table Of Contents
- Table of Contents
- General Information
- Specifications
- Installation
- Location
- Dimensions: IQ Radar 300 with Rod Antenna
- Dimensions: Threaded Rod
- Dimensions: Horn
- Mounting
- Rod Assembly
- Mounting: Rod Assembly
- Mounting: Manhole Covers
- Mounting: Horn Antennas
- Mounting: Waveguide Antenna
- Mounting: Stillpipe or Sidepipe
- Mounting: Horn with Waveguide Extensions
- Mounting: Sanitary Mounting
- Mounting: Location
- Interconnection
- Start Up
- Operation(
- Application Examples
- Parameter Descriptions
- _
- _
- Quick Start Parameters (P001 to P007)
- Volume Parameters (P050 to P053)
- Display and Reading Parameters (P060 to P063)
- Fail-Safe Parameters (P070 to P072)
- mA Parameters (P200 to P219)
- Independent mA Setpoints Parameters (P210 and P211)
- Profile Record Parameters (P330 to P337)
- Auto Record ON and OFF Setpoint Parameters (P334 to P337)
- Installation Records Parameter
- Range Calibration Parameters
- Rate Parameters
- Measurement Verification Parameters
- Communication Parameters
- Echo Processing Parameters
- Algorithm Parameters
- TVT Adjustment Parameters
- P837 Auto Near TVT
- Test Parameters
- _
- Communications: Modbus Register Map
- Communications: Data Types
- Error Handling
- Troubleshooting
- Maintenance(
- Appendix I
- Appendix II
- Appendix III
- Appendix IV
- Appendix V
PL-611 IQ Radar 300 Page 31
Installation
Installation
Installation
Installation
Mounting: Horn with Waveguide Extensions
In applications where the standpipe is too long
and the diameter is too small (such as a
standpipe that is 100mm (4”) in diameter and
460mm (18”) in length), the rod antenna is not
suitable due to standpipe interference. In this
case, use the waveguide/horn combination.
Waveguide extensions are available in custom
lengths.
Note:
Note:Note:
Note: The IQ 300 maximum range of ??m is reduced by [0.64 x waveguide length].
Blanking and offset parameters are set by Milltronics. See the device tag for values.
Mounting: Sanitary Mounting
There are two common sanitary mounting options; the 2”, 3”, and 4” tri-clamp with rod
antenna and the sanitary 4” horn antenna.
Wetted Parts:
W
etted Parts:Wetted Parts:
W
etted Parts:
PTFE or UHMW-PE only.
If the horn diameter is too large for the standpipe
opening, you need to insert it from inside the vessel.
The horn must be connected to the IQ 300 process
flange.