User's Manual

Table Of Contents
PL-611 IQ Radar 300 Page 17
Installation
Installation
Installation
Installation
Dimensions: Threaded Rod
50mm
(2)
100mm
(4)
optional
extension
standard antenna
Teflon paste
(supplied)
Note:
Ingress of water or process fluids into the connecting threads
can cause reflections at the connection, appearing as false
echoes.
Apply Teflon paste to threads and tighten slowly. Ensure that
the rod sections mate securely with no gaps. Do not apply too
much Teflon paste or parts will not mate securely.
Do not use wrenches or pliers. Hand tight only.
Sealant must have
ε
r
< 3
. We recommend a sealant such as
Teflon paste or silicone compound.