- Specifications
- Installation
- Location
- Dimensions: IQ Radar 300 with Rod Antenna
- Dimensions: Threaded Rod
- Dimensions: Horn
- Mounting
- Rod Assembly
- Mounting: Rod Assembly
- Mounting: Manhole Covers
- Mounting: Horn Antennas
- Mounting: Waveguide Antenna
- Mounting: Stillpipe or Sidepipe
- Mounting: Horn with Waveguide Extensions
- Mounting: Sanitary Mounting
- Mounting: Location
- Interconnection
- Start Up
- Operation(
- Application Examples
- Parameter Descriptions
- _
- _
- Quick Start Parameters (P001 to P007)
- Volume Parameters (P050 to P053)
- Display and Reading Parameters (P060 to P063)
- Fail-Safe Parameters (P070 to P072)
- mA Parameters (P200 to P219)
- Independent mA Setpoints Parameters (P210 and P211)
- Profile Record Parameters (P330 to P337)
- Auto Record ON and OFF Setpoint Parameters (P334 to P337)
- Installation Records Parameter
- Range Calibration Parameters
- Rate Parameters
- Measurement Verification Parameters
- Communication Parameters
- Echo Processing Parameters
- Algorithm Parameters
- TVT Adjustment Parameters
- P837 Auto Near TVT
- Test Parameters
- _
- Communications: Modbus Register Map
- Communications: Data Types
- Error Handling
- Troubleshooting
- Maintenance(
- Appendix I
- Appendix II
- Appendix III
- Appendix IV
- Appendix V
PL-611 IQ Radar 300 Page 13
Specifications
Specifications
Specifications
Specifications
• temperature: UHMW-PE -40 to 80°C (-40 to 176°F)
PTFE -40 to 200°C (-40 to 392°F)
5
• pressure (vessel): dependant on process connection type and
temperature. Refer to Appendix IV on page 101
for charts.
Approvals (refer to device nameplate)
• safety: CSA
NRTL/C
, CE, FM
• radio: BAPT, Industry Canada, FCC
Hazardous areas:
• IQ Radar 300: Cenelec/Sira
6
, EEx de IIB+H
2
T6 (Note: antenna
may be used in Zone 0 environments).
FM (USA) Class I, Div 1, Group A, B, C, D. Class
II/III, Div. 1, Group E, F, G(Class I, Zone 1 IIC T6)
CSA Class I/II, Div. 1, Group B, C, D, E,F, G.CE,
CSA
NRTL/C
FM (non-hazardous)
Canadian Registration Number (CRN) for pressure fittings:
7
• Ontario, British Columbia, Alberta: OF6494.512
• others pending
• 3A Sanitary
Note: Contact Milltronics for complete and up-to-date list of approvals.
Programmer (remote keypad)
• enclosure: general purpose
67mm w x 100mm h x 25mm d
(2.6" w x 4" h x 1" d)
• ambient temperature: -20 to 50° C (-5 to 122° F)
• interface: proprietary infrared pulse signal
• power: 9V battery (ANSI/NEDA 1604, PP3 or equivalent)
• weight: 150g (0.3 lb)
5 See Temperature De-rating on page 97 and Approvals on page 13.
6 Approved for PTFE material only
7 All process connections except for the sliding waveguide