Operating Instructions

"Button Pressed" event message
This event message is sent after the F1 function key has been pressed or released. If you want
to adapt the short/long press functionality, you need to change the parameter involved in the
configuration file, "RTLS_LM_DataExport.ini".
URI "agilion.wls.epaper.button_pressed"
Parameter Consists of:
TransponderID, type: UInt64
ButtonID, type: UInt32
ButtonDown, type: UInt32
The following happens when you briefly press the F1 function key:
Value Description
0 Evaluated as not pressed
OnShortButtonPress = 0
Function key briefly pressed > Event parameter: ButtonDown = 0
Function key pressed long (> 2 seconds) > Event parameter: Button‐
Down = 1
After a short or long press and subsequent heartbeat > Event parame‐
ter: ButtonDown = 0
1 Considered pressed
OnShortButtonPress = 1
Function key pressed short or long > Event parameter: ButtonDown = 1
After a short or long press and subsequent heartbeat > Event parame‐
ter: ButtonDown = 0
The default value is 1 in the configuration file "RTLS_LM_DataExport.ini".
3.5 Code examples
Code example WAMP connection
{
"wamp": {
"url": "ws://127.0.0.1:12344/",
"realm": "agilion.wls",
"user": "Administrator",
"key": "Agilion2011"
}
}
Programming interface
3.5 Code examples
SIMATIC RTLS4083T
Operating Instructions, 03/2020, C79000-G8976-C527-03 19