Operating instructions
Attachment
24 EB 8390 EN
5.3.1 Preparations
Version with integrated solenoid valve
(Type 3738-20-xxx1400xxx000) (Fig. 10)
Two mounting platforms are available for the
attachment (Fig. 9):
−
Standard mounting platform for mount-
ingontoPfeifferType31bRotaryActua-
tor with integrated air holes
−
Mounting platform for piping as required
for mounting to standard actuators ac-
cordingtoVDI/VDE3845
The supply air is connected at the side of both
mounting platforms. The blanking plug needs
to be removed from the air connection.
1.
Insert the molded seal (3) into the mount-
ing platform (2) depending on the type of
actuator (single-acting or double-acting).
2.
Push the O-ring (3.1) onto the air duct of
the molded seal (3).
3.
Press the molded seal (4) onto the air
ducts underneath the mounting platform
(2).
4.
For attachment to rotary actuators with a
50mm shaft height:
Press the second molded seal (4) onto the
air ducts underneath one of the distance
pieces (5).
5.
Remove the blanking plug on the supply
air port (SUPPLY) of the mounting plat-
form (2).
Version with external solenoid valve
(Type3738-20-xxx1000xxx00)
No preparation is necessary.
Supply pressure
Standard mounting platform
(1380-1266 or 1380-1268)
Supply pressure
Mounting platform with piping as required
(1380-1738 or 1380-1739)
Fig. 9: Mounting platform