Parameter 6
Defrost cycle
Range: 30 to 90 min
Default: 45 min
Adjustable by technicians
Parameter 7
Enter defrost mode
Range: -30 to 0 deg C
Default: -7
Adjustable by technicians
Parameter 8
Exit defrost mode
Range: 2 to 30 deg C
Default: 13
Adjustable by technicians
Parameter 9
Exit defrost backup mode
Range: 1 to 12 min.
Default: 8 min
Adjustable by technicians
Parameter 10
Not applicable on this model
Parameter 11
Discharge temperature setting
of compressor to open the
solenoid valve
Range: 70 to 120 deg C
Default: 95 deg C
Adjustable by technicians
Parameter 12
Discharge temperature setting
of compressor to close the
solenoid valve
Range: 60 to 80 deg C
Default: 70
Adjustable by technicians
Parameter 13
Enter over temperature
compressor protection cut-out
Range: 90 to 127 deg C
Default: 105
Adjustable by technicians
ELEC
TIMER
CLOCK
SET
MIN
ELEC
TIMER
CLOCK
SET
Parameter 4
Not applicable on this model
Parameter 5
Not applicable on this model
Parameter 3
Not applicable on this model
ELEC
TIMER
CLOCK
SET
MIN
Parameter 0
Domestic hot water tank temperature
Range: 60 to 70 deg C
Default: 60
Adjustable
Parameter 1
Deadband temperature for re-heating
Range: 2 to 15 deg C
Default: 8
Adjustable by technicians
Parameter 2
Not applicable on this model
ELEC
TIMER
CLOCK
SET
ELEC
TIMER
CLOCK
SET
ELEC
TIMER
CLOCK
SET
13
ELEC
TIMER
CLOCK
SET
ELEC
TIMER
CLOCK
SET
C
Parameter 14
Exit over temperature
compressor protection cut-out
Range: 60 to 80 deg C
Default: 70
Adjustable by technicians
ELEC