AIR TO WATER ALL IN ONE HEAT PUMP Owner’s Manual Installation and Warranty http://www.siddonssolarstream.
AIR TO WATER ALL IN ONE HEAT PUMP Contents 1. ONE OF THE WORLD'S MOST EFFICIENT WAYS TO HEAT WATER .................... 3 2. FEATURES OF YOUR SOLARSTREAM.............................................................. 3 2.1 Storage Tank.............................................................................................. 3 2.2 Heat Exchanger.......................................................................................... 3 2.3 Centrifugal Fan..................................................
AIR TO WATER ALL IN ONE HEAT PUMP Contents 7. MAINTENANCE & SERVICE INFORMATION................................................. 10 7.1 Heating Time............................................................................................. 10 7.2 Air Evaporator Coils.................................................................................. 10 7.3 PTR valve maintenance............................................................................. 10 7.4 Adding an Expansion Control Valve (ECV).......
AIR TO WATER ALL IN ONE HEAT PUMP 1. ONE OF THE WORLD'S MOST EFFICIENT WAYS TO HEAT WATER C ongratulations for purchasing a Siddons Solarstream Macon energy efficient Heat Pump Water Heater, designed for Australian conditions, to produce low energy hot water for many years. In simple terms, this water heater typically uses just one quarter of the energy of a conventional electric element water heater by absorbing heat from the surrounding air of between -5 and 45 degrees C, night and day.
AIR TO WATER ALL IN ONE HEAT PUMP 2.4 Installation overview To install your Solarstream, site the unit vertically without leaning on a concrete plinth and ensure it will remain in a vertical position throughout its usable life and not lean over due to possible erosion of soil under the plinth, or such risk. Adhere to the relevant plumbing regulations in regard to the water heater installation. We recommend fixing the tank to the adjacent wall as an added safety precaution.
AIR TO WATER ALL IN ONE HEAT PUMP 3. SPECIFICATIONS & DIMENSIONS 3.1 Technical parameters for the main unit Model MAHRW 010ZAB-270(01) 010ZAB-340(01) S010ZAB-270(01) S010ZAB-340(01) W 4100 4100 4100 4100 BTU/h 14000 14000 14000 14000 Input power W 1150 1150 1150 1150 Rated Current A 5.2 5.2 5.2 5.2 Max.Current A 6.5 6.5 6.5 6.
AIR TO WATER ALL IN ONE HEAT PUMP 3.2 Main unit appearance and mounting dimension A A SIDDONS SIDDONS B C B C 1090mm 880mm 30mm Type A B C MAHRW010ZAB-270(01) ¦700 1595 1105 MAHRW010ZAB-340(01) ¦700 1775 1315 MAHRWS010ZAB-270(01) ¦700 1595 1105 MAHRWS010ZAB-340(01) ¦700 1775 1315 30mm 4 INSTALLATION DETAILS 4.1 General Installation Requirements This water heater must be installed by a licensed trades person in accordance with: 1) AS 3500.
AIR TO WATER ALL IN ONE HEAT PUMP 4.4 Pressure and Temperature Relief Valve (PTR) The Pressure and Temperature Relief valve supplied with the unit is rated at 850 kPa pressure and must be fitted to the top front socket and made accessible so that the release mechanism can be operated and, if required, replaced. The outlet of the PTR valve must be suitably drained to remove the water discharged during the normal heating cycle. The valve thread is G1/2/20mm.
AIR TO WATER ALL IN ONE HEAT PUMP 4.7 Pressure Limiting Valve Your Solarstream is designed for direct connection to a maximum water supply pressure of 500kpa. A Pressure Limiting Valve (complying with AS1357) set at 500 kPa must be fitted to the cold-water supply line or you will void your warranty. (Refer Section 13.2) This device must be installed after the isolating valve. 4.
AIR TO WATER ALL IN ONE HEAT PUMP Safety Notes Note.1: This water heater is fitted with a thermostat and over-temperature power cut-out (both incorporated into the digital controller). Under no circumstances should the water heater be operated without both of these devices being in the circuit. Only a qualified technician or the manufacturer should carry out replacement. Note.2: If the supply cord is damaged, the technician must replace it in order to avoid hazard.
AIR TO WATER ALL IN ONE HEAT PUMP 6. SAFETY INFORMATION WARNING: For safe performance, this water heater is fitted with: 1) Digital Controller 2) Thermostat (connected to the digital controller) to manage water temperature 3) Thermostat (connected to the digital controller) to manage compressor temperature 4) Non self-setting thermal cut out switch (incorporated into the digital controller) 5) Pressure & Temperature Relief valve These devices must not be tampered with or removed.
AIR TO WATER ALL IN ONE HEAT PUMP 7.5 Thermal Overload (Incorporated into Digital Controller) All models are fitted with a digital controller for heat pump management. One function of the digital controller is to initiate a shut down and lockout if the compressor reaches a temperature of 105 degrees C. The heat pump will not automatically restart from this. Turning the power off then back on will perform a re-set operation. 7.
AIR TO WATER ALL IN ONE HEAT PUMP 8.1 Mounting and Fixing Method of the Remote Controller NOTE: On this model, the Controller is fixed under the lid. Illustration 2 Illustration 1 Use flat screwdriver to press down the two tabs Remove the top covering leftwards to disengage and lift open the face covering. two top tabs.
AIR TO WATER ALL IN ONE HEAT PUMP SET SET SET SET MIN ELEC TIMER CLOCK Parameter 0 Domestic hot water tank temperature Range: 60 to 70 deg C Default: 60 Adjustable SET ELEC ELEC TIMER CLOCK Parameter 1 Deadband temperature for re-heating Range: 2 to 15 deg C Default: 8 Adjustable by technicians SET TIMER CLOCK Parameter 2 Not applicable on this model SET MIN ELEC TIMER CLOCK Parameter 3 Not applicable on this model SET MIN C ELEC TIMER CLOCK Parameter 4 Not applicable on this model
AIR TO WATER ALL IN ONE HEAT PUMP 8.4 Operational Data Setting The unit's operational data can be set using the controller display unit. Parameters should be set according to the table below.
AIR TO WATER ALL IN ONE HEAT PUMP 9. RECOGNITION OF ABNORMAL OPERATION 9.1 Start up Delay NOTE: The heat pump has a 3-minute time delay on re-start. If the power to the heat pump is cut during its heating cycle, then a time delay period will commence upon re-start. The compressor and fan will not operate until the completion of this delay period. 9.2 Continuous Trickle If you notice a continuous trickle of water from the PTR valve, this is likely due to a build up of grit or scale.
AIR TO WATER ALL IN ONE HEAT PUMP 10. SYSTEM SIGNAL LIGHTS Motherboard signal lights Malfunction and Protection Name Off Standby On Normal start PP1 1 flash 1 off Bottom of water tank temp. sensor failure PP2 2 flash 1 off Not applicable 3 flash 1 off System coil temp. sensor failure PP4 4 flash 1 off Compressor discharge temp.
AIR TO WATER ALL IN ONE HEAT PUMP 11. TROUBLESHOOTING GUIDE Malfunction Reason Solution 1.Turn off power and inspect power supply 2.Identify the cause and rectify 3.Identify the cause and replace with new fuse Unit does not work 1.Power failure 2.Loose power wire connection 3.Fuse of controller blown The pump is operating, but water isn't circulatory or the noise of pump is too loud 1.Shortage of water or air in the water system 1.
AIR TO WATER ALL IN ONE HEAT PUMP 12. WIRING DIAGRAM Water cycle Pump Solenoid valve Fan Red Y/G Compressor Electrical heating Solar collector temp.(5K resistor) 1 Discharge temp. Coil temp. White Red C Y/G R COM S Blue Blue Capacitance Ambient temp. Run indicator Black Blue Brown Blue Four-way valve Top of tank temp.(5K resistor) Bottom of tank temp.
13. WARRANTY POLICY 13.1 Warranty Terms Cover Period The following warranty policy for your Solarstream Heat Pump Water Heater applies from the date of despatch from Siddons. The warranty for the various components of your Solarstream is set out below. NOTE: In the Warranty Policy below, we define PURE WATER as coming from reservoirs supplied by mountain water including the Great Dividing Range and Tasmania.
13.3 Exclusions The following warranty exclusions may cause your Solarstream warranty to become void, and which may incur a service charge and cost for parts should this become necessary: 1. Where service is required to reconnect the operation of the Solarstream due to problems related with abnormal water supply such as high water pressure, faulty plumbing and/or electrical wiring, or major variations in electricity supply; 2.