Datasheet
V180-2
2010-06-24 SICK 11
Subject to change without notice
Scanning range SR, typ. max. 0 ... 28 m
Operating range 0 ... 20 m
Light spot diameter Approx. 1,100 mm at 20 m
Angle of dispersion sender
Approx. 5°
Light source
1)
, light type LED, red light, 645 nm
Sensitivity adjustable
Receiver VE180-2: Potentiometer 270°
Orange LED indicator Switching output active
Green LED indicator Stability indicator light reception
LED lights continuously:
light reception < 0.9/> 1.1
LED off: light reception > 0.9 ... < 1.1
Supply voltage V
S
10 ... 30 V DC
2)
Residual ripple
3)
± 10 %
Current consumption sender
4)
≤ 20 mA
Current consumption receiver
4)
≤ 15 mA
Switching outputs Q: PNP, open collector
Signal voltage PNP HIGH/LOW V
S
– 1.8 V
max
/approx. 0 V
Q: NPN, open collector
Signal voltage NPN HIGH/LOW Approx. V
S
/< 1.8 V
Switching mode Receiver Light-/dark-switching, selectable
5)
Output current I
A
max. ≤ 100 mA
Response time
6)
≤ 0.5 ms
Max. switching frequency
7)
1,000/s
Connection type
Plug, M12, 4-pin
Sender
Cable
8)
, PVC, 2 m, 2 x 0.18 mm
2
, Ø 3.8 mm
Receiver
Cable
8)
, PVC, 2 m, 4 x 0.18 mm
2
, Ø 3.8 mm
VDE protection class
Enclosure rating IP 67
Circuit protection
9)
A, B, C
Ambient temperature T
A
Operation –25 °C ... +55 °C
Storage –40 °C ... +70 °C
Weight plastic housing
10)
With plug M12, approx. 18 g
With cable 2 m, approx. 62 g
Weight metal housing
10)
With plug M12, approx. 47 g
With cable 2 m, approx. 95 g
Housing material Housing: PBT and PC
Housing: brass nickel-pated and PC
Optic: PMMA
P41137
Technical data VSE180-2
P42437 N41137 N42437
P41132 P42432 N41132 N42432
1)
Average service life 100,000 h
at T
A
= +25 °C
2)
Limit values
3)
May not exceed or fall short of
V
S
tolerances
4)
Without load
5)
L/D-switching type control line:
L/D = +
V
S
: light-switching L.ON
L/D = 0 V: dark-switching D.ON
Control line open
NPN: light-switching L.ON
PNP: dark-switching D.ON
6)
Signal transit time with resistive load
7)
With light/dark ratio 1:1
8)
Do not bend below 0 °C
9)
A = V
S
connections reverse-polarity
protected
B = Inputs and outputs reverse-polarity
protected
C = Outputs overcurrent and short-
circuit protected
10)
Per sender or receiver
Scanning range and operating reserve
Model name Part No.
*)
VSE180-2N41137
VSE180-2N42437
VSE180-2P41137
VSE180-2P42437
VSE180-2N41132
VSE180-2N42432
VSE180-2P41132
VSE180-2P42432
6037497
6037498
6037499
6037500
6041820
6041821
6041822
6041823
Ordering information
*)
Part No. includes sender and receiver
(pair)
0(m) 10 20 30
Operating range Scanning range typ. max.
28020
(m) 10 20 30
Scanning range
100
2
10
1
Function reserve
VSE180-2
Scanning range typ. max.
Operating range