Brochure

Scanning distance
Scanning distance
100 mm
Scanning distance
400 mm
Scanning distance
200 mm
(mm) 10 100 1000
100
10
1
Function reserve
VT 18 - CA / 400 mm
90 %
Scanning distance, max. typical
Operating distance
(mm) 10 100 1000
100
10
1
VT 18 - AC / 200 mm
Function reserve
Scanning distance, max. typical
Operating distance
90 %
VT 18-2
(mm) 10 100 1000
100
10
1
Function reserve
Scanning distance, max. typical
Operating distance
VT 18 – AC/ 100 mm
90 %
953
05-08-2006 SENSICK CATALOGUE
Technical data VT 18-2T
1112
1)
1410
1)
1132
1)
1430
1)
1152
1)
1450
1)
Type
Order information
Order no.
1)
Light-switching
2)
Dark-switching
3)
Object with 90 % reflectance
(referred to standard white DIN 5033
4)
Average service life 100,000 h
at T
A
= +2C
5)
Limit values
6)
Without load
7)
With resistive load
8)
With light/dark ratio 1:1
9)
Do not bend below 0 °C
10)
Reference voltage 250 V AC
11)
C = Interference suppression
2112
2)
2410
2)
2132
2)
2430
2)
2152
2)
2450
1)
Housing Straight
Scanning distance, max. typical
2 mm... 100 mm
3)
Recommended operating distance
3 mm... 90 mm
3)
Light source
4)
, light type LED, infrared light
Light spot diameter Approx. 12 mm at 100 mm
Angle of dispersion of sender Approx. 3.5°
Scanning distance, max. typical
2 mm... 200 mm
3)
Recommended operating distance
3 mm... 180 mm
3)
Light source
4)
, light type LED, infrared light
Light spot diameter Approx. 24 mm at 200 mm
Angle of dispersion of sender Approx. 3.5°
Scanning distance, max. typical
2 mm... 400 mm
3)
Recommended operating distance
3 mm... 360 mm
3)
Light source
4)
, light type LED, infrared light
Light spot diameter Approx. 48 mm at 400 mm
Angle of dispersion of sender Approx. 3.5°
Supply voltage V
S
5)
20 ...253 V AC/50 ... 60 Hz
Current consumption
6)
30 mA
Switching output TRIAC
Switching current I
A
max. 5 ... 300 mA
voltage drop 3 V max. (U = 250 V AC)
max. switching current 6 A/10 ms; f = 10 Hz
leakage current max. 1.5 mA (V
S
= 250 V AC)
Switching voltage V
S
Light receiver, switching mode Light-switching
Response time
7)
20 ms
Max. switching frequency
8)
25/s
Connection types cable PVC, 2 m
9)
; 3 x 0.34 mm
2
, l 4.7 mm
plug M12, 4-pin
VDE protection class
10)
V
Circuit protection
11)
C
Enclosure rating IP 67
Ambient temperature T
A
25 °C...+70 °C
Weight with connection cable Approx. 95 g
with equipment plug Approx. 30 g
Housing material Housing: PBT/PC; optic: PMMA
VT 18-2T 1450
VT 18-2T 1152
VT 18-2T 1430
VT 18-2T 1132
VT 18-2T 1410
VT 18-2T 1112
6 011 375
6 011 372
6 011 374
6 011 371
6 011 373
6 011 370
VT 18-2T 2450
VT 18-2T 2152
VT 18-2T 2430
VT 18-2T 2132
VT 18-2T 2410
VT 18-2T 2112
6 022 099
6 022 098
6 022 097
6 022 096
6 022 095
6 022 094
KD01_V18_en.qxd 17.07.2006 15:15 Uhr Seite 953