Datasheet

0 (m) 0.5 1.0 1.5 2.0 2.5 3.0
Operating range Scanning range, max. typical
0 2.50.03 2.0
0 2.30.03 1.8
0.90.1 0.7
2.80.03 2.3
2
3
4
1
0.1 ... 0.7 mReflective tape
Diamond Grade
PL 50 A/PL 40 A/
P 250
4
0.03 ... 1.8 m
3
C 110
0.03 ... 2.0 m
2
PL 80 A 0.03 ... 2.3 m
1
Reflector type
Operating range
VL 12-2
1000
100
10
1
1.0 1.5 2.0 2.50.5(m)
Operating range
Operating range
Reflector
C 110
Scanning range, max. typical
VL 12-2
2
927
05-08-2006 SENSICK CATALOGUE
Scanning range, max. typ./reflector
0.03
... 2.8 m/PL 80 A
Operating range
0.03
... 2.3 m/PL 80 A
Sensitivity setting Not available
Light source
1)
, light type LED, red light, with polarization filter
Light spot diameter Approx. 80 mm at 2 m
Angle of dispersion of sender Approx. 2.3° (SR = max.),
Approx. 6.3° (SR = 1/2 max.)
Supply voltage V
S
10 … 30 V DC
2)
Ripple
3)
10 %
Current consumption
4)
20 mA
Switching outputs Q: PNP
Q: NPN
Output current l
A
max. 100 mA
Switching mode Light-/Dark-switching selectable
5)
Response time
6)
1.25 ms
Switching frequency max.
7)
400/s
Connection types Cable
8)
PVC, 2 m, 4 x 0.14 mm
2
, Ø 3.75 mm
Plug M12, 4-pin
VDE protection class
9)
V
Circuit protection
10)
A, B, C, D
Enclosure rating IP 67
Ambient temperature T
A
Operation 25 °C ... + 70 °C
Storage 25 °C ... + 70 °C
Weight With cable Approx. 54 g
With plug Approx. 18 g
Housing material Housing: Nickel-coated brass/PA
Optics: PC
1)
Average service life 100,000 h
at T
A
= +2C
2)
Limit values
3)
May not exceed or fall short of
V
S
tolerances
4)
Without load
5)
L/D switching type control line
L/D = open (not assigned)
dark-switching D.ON
L/D = + V
S
: light-switching L.ON
L/D = 0 V: dark-switching D.ON
6)
Signal transit time with resistive load
7)
With light/dark ratio 1:1
8)
Do not bend below 0 °C
9)
Reference voltage 50 V DC
10)
A=V
S
connections reverse-polarity
protected
B = Inputs and output reverse-polarity
protected
C = Interference pulse suppression
D = Outputs overload and short-circuit
protected
Technical data VL 12-2
P 132 P 430 N 132 N 430
Scanning range and operating reserve
Type Order no.
VL 12-2P 132
6 026 219
VL 12-2P 430
6 026 220
VL 12-2N 132
6 026 217
VL 12-2N 430
6 026 218
Order information
KD01_V12_2_en.qxd 17.07.2006 14:08 Uhr Seite 927