Datasheet
UE403-A0930 | UE403
SAFETY RELAYS
Inputs: override, reset, C1, belt stop, muting
sensors
ON state, switching voltage HIGH 24VDC (11VDC... 30VDC)
OFF state, switching voltage LOW 0VDC (–30VDC... 5VDC)
Input current HIGH 6mA... 15mA
Input current LOW –0.5mA... 1.5mA
Outputs: voltage supply for reset, override,
C1
Supply voltage 24VDC (15VDC... 28.8VDC)
Output current
≤ 400mA
2)
Outputs: muting sensors
Supply voltage 24VDC (15VDC... 28.8VDC)
Output current
≤ 500mA
2)
Muting lamp
Output current HIGH (monitored)
20mA... 400mA
3)
Output current HIGH (not monitored)
0mA... 400mA
3)
1)
Via connected ESPE.
2)
Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1in each case): max. 1000mA.
3)
At max. 5W power consumption.
Mechanical data
Dimensions (Wx Hx D)
76.5mmx 225.2mmx 40mm
Weight
+600g
Mounting
Flexible mounting on the M4000 Advanced or directly in the system
Ambient data
Enclosure rating
IP65 (IEC60529)
Ambient operating temperature
–30°C... +55°C
Storage temperature
–30°C... +70°C
Classifications
ECl@ss 5.0
27371990
ECl@ss 5.1.4
27371990
ECl@ss 6.0
27371819
ECl@ss 6.2
27371819
ECl@ss 7.0
27371819
ECl@ss 8.0
27371819
ECl@ss 8.1
27371819
ECl@ss 9.0
27371819
ETIM 5.0
EC001449
ETIM 6.0
EC001449
UNSPSC 16.0901
41113704
2018-11-26 12:21:14 | Online data sheet
Subject to change without notice
SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK 3