Datasheet

UE403-A0930 | UE403
SAFETY RELAYS
Inputs: override, reset, C1, belt stop, muting
sensors
ON state, switching voltage HIGH 24VDC (11VDC... 30VDC)
OFF state, switching voltage LOW 0VDC (–30VDC... 5VDC)
Input current HIGH 6mA... 15mA
Input current LOW –0.5mA... 1.5mA
Outputs: voltage supply for reset, override,
C1
Supply voltage 24VDC (15VDC... 28.8VDC)
Output current
≤ 400mA
2)
Outputs: muting sensors
Supply voltage 24VDC (15VDC... 28.8VDC)
Output current
≤ 500mA
2)
Muting lamp
Output current HIGH (monitored)
20mA... 400mA
3)
Output current HIGH (not monitored)
0mA... 400mA
3)
1)
Via connected ESPE.
2)
Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1in each case): max. 1000mA.
3)
At max. 5W power consumption.
Mechanical data
Dimensions (Wx Hx D)
76.5mmx 225.2mmx 40mm
Weight
+600g
Mounting
Flexible mounting on the M4000 Advanced or directly in the system
Ambient data
Enclosure rating
IP65 (IEC60529)
Ambient operating temperature
–30°C... +55°C
Storage temperature
–30°C... +70°C
Classifications
ECl@ss 5.0
27371990
ECl@ss 5.1.4
27371990
ECl@ss 6.0
27371819
ECl@ss 6.2
27371819
ECl@ss 7.0
27371819
ECl@ss 8.0
27371819
ECl@ss 8.1
27371819
ECl@ss 9.0
27371819
ETIM 5.0
EC001449
ETIM 6.0
EC001449
UNSPSC 16.0901
41113704
2018-11-26 12:21:14 | Online data sheet
Subject to change without notice
SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK 3