Datasheet
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
UE403-A0930 | UE403
SAFETY RELAYS
Illustration may differ
Ordering information
Type Part no.
UE403-A0930 1026287
Other models and accessories www.sick.com/UE403
Detailed technical data
Safety-related parameters
Safety integrity level
SIL3 (IEC61508)
SILCL3 (EN62061)
Category
Category 4(ENISO13849)
Performance level
PLe(ENISO13849)
PFH
D
(mean probability of a dangerous fail-
ure per hour)
1.0x10
-8
(ENISO13849)
1)
T
M
(mission time)
20years (ENISO13849)
1)
1)
Only in conjunction with M4000 Advanced, M4000 Advanced A/P and M4000 Advanced Curtain.
Functions
Concurrence monitoring
✔
Monitoring of total muting time
✔
Sensor gap monitoring
✔
Belt stop
✔
Muting with override
✔
Exit monitoring
✔
End of muting by ESPE
✔
Interfaces
Connection type
Female connector M12, 5-pin
Electrical data
Protection class
III (IEC61140)
Supply voltage V
S
24VDC (19.2VDC... 28.8VDC)
1)
Power consumption
≤ 2A
1)
Via connected ESPE.
2)
Total of all supply currents from the connections RES/OVR, A1, A2, B1 and B2 (pin 1in each case): max. 1000mA.
3)
At max. 5W power consumption.
2 SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK Online data sheet | 2018-11-26 12:21:14
Subject to change without notice