Datasheet
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
UE10-2FG2D0 | UE10-2FG
SAFETY RELAYS
Illustration may differ
Ordering information
Type Part no.
UE10-2FG2D0 1043915
Other models and accessories www.sick.com/UE10-2FG
Detailed technical data
Safety-related parameters
Safety integrity level
SIL3 (IEC61508)
1)
SILCL3 (EN62061)
1)
Category
Category 4(ENISO13849)
1)
Performance level
PLe(ENISO13849)
1)
B
10d
parameter
1x10
5
switching cycles (AC-15, 230V, I= 2A)
2.5x10
5
switching cycles (AC-15, 230V, I= 1A)
5.4x10
5
switching cycles (DC-13, 24V, I= 0.5A)
1x10
7
switching cycles (DC-13, 24V, I ≤ 2A)
PFH
D
(mean probability of a dangerous fail-
ure per hour)
7.0x10
-10
(ENISO13849)
T
M
(mission time)
20years (ENISO13849)
1)
If the feedback current path Y1 - Y2 (external device monitoring) is monitored using an appropriate main unit.
Interfaces
Connection type
Fixed screw terminals
Number of enable current (N/O) contacts
2, relevant for safety
Number of contactor monitoring (N/C) con-
tacts
1
Electrical data
Operating data
Voltage supply
B1/A2, B2/A2
Output circuit > 25VAC / 60VDC PELV
Output circuit ≤ 25VAC / 60VDC PELV or SELV
Residual ripple
(≤ 2.4V
pp
)
1)
Power consumption
(≤ 2W (DC))
1)
In DC operation, within the limits of V
S
.
2 SENS:CONTROL - SAFE CONTROL SOLUTIONS | SICK Online data sheet | 2018-09-11 15:13:28
Subject to change without notice