PRESSURE SENSORS
Supply voltage
8VDC... 30VDCwithoutput signal 4mA... 20mA and 0V... 5V
14VDC... 30VDCwith output signal 0V... 10V
8VDC... 30VDC
1)
Power consumption
Signal current (max. 25mA) for current output
Max. 8mA for voltage output signal
Electrical safety
Overvoltage protection: 32VDC, 36VDC with 4mA... 20mA
Short-circuit protection: Q
A
towards M
Reverse polarity protection: L
+
to M
Protection class: III
Isolation voltage
500VDC
CE-conformity
Pressure equipment directive: 2014/68/EU, EMC directive: 2014/30/EU, EN61 326-2-3
Weight sensor
Approx.80g
Seal
NBR
Enclosure rating
IP67
Protection class III
Reference conditions
Reference conditions: According to IEC61298-1
1)
The pressure transmitter must be supplied with power by a limited energy circuit compliant with 9.3of UL/EN/IEC601010-1 or LPS to UL/EN/IEC60950-1 or Class
2to UL 1310/UL1585 (NEC or CEC). The power supply must be suitable for operation above 2,000m if the pressure transmitter is used above this altitude.
Ambient data
Ambient temperature
0°C... +80°C
Storage temperature
–40°C... +70°C
Relative humidity
45%... 75%
Shock load
500g according to IEC60068-2-27 (mechanical shock)
Vibration load
10g according to IEC60068-2-6 (vibration under resonance)
20g optional
Classifications
ECl@ss 5.0
27200614
ECl@ss 5.1.4
27200614
ECl@ss 6.0
27200614
ECl@ss 6.2
27200614
ECl@ss 7.0
27200614
ECl@ss 8.0
27200614
ECl@ss 8.1
27200614
ECl@ss 9.0
27200614
ETIM 5.0
EC002476
ETIM 6.0
EC002476
UNSPSC 16.0901
41112410