Datasheet
2 0 0 9 - 0 8 - 1 1 S I C K 7
Scanning distance SD, typ. max.
1)
10 ... 100 mm
Operating distance SD
1)
10 ... 90 mm
Light spot diameter Approx. 20 mm at 100 mm
Angle of dispersion sender Approx. 4.5°
Light source
2)
, light type LED infrared, 950 nm
Optical axis laixA
Sensitivity adjustable Potentiometer 270°
Light reception indicator Yellow LED: lights continuously:
3.1 > rotcaf evreseR
3.1 < ... 0.1 > rotcaf evreser :sknilB
Supply voltage V
S
10 ... 30 V DC
3)
Residual ripple
4)
≤ 5 V
PP
Current consumption
5)
≤ 30 mA
Switching outputs Q: PNP
:Q NPN
Signal voltage HIGH V
S
– 2.9 V
V
S
Signal voltage LOW Approx. 0 V
≤ 2.9 V
Switching mode Light-switching
gnihctiws-kraD
Output current I
A
max. ≤ 100 mA
Response time
6)
≤ 1.25 ms
Max. switching frequency
7)
400/s
Connection type
8)
Plug M12, 4-pin
Protection clas (IEC 61140)
Enclosure rating
IP 67, IP 69K acc. to DIN 40050
Certificates
9)
ECOLAB, JohnsonDiversey
Circuit protection
10)
A, B, C
Ambient temperature T
A
Operation –25 °C ... +55 °C
Storage –25 °C ... +70 °C
Weight with plug Approx. 50 g
Housing material Housing: 100 % stainless steel 1.4404
dna denedrah ecafrus ,mm 3 AMMP :citpO
tempered
P3217V
1)
Object with 90 % remission (based on
standard white DIN 5033);
100 x 100 mm
2)
Average service life 100,000 h
at T
A
= +25 °C
3)
Limit values
4)
May not exceed or fall short of
V
S
tolerances
5)
Without load
6)
Signal transit time with resistive load
7)
With light/dark ratio 1:1
8)
Gold-plated contact pins
9)
Refer to the corresponding certificates
for details
10)
A = V
S
connections reverse-polarity
protected
B = Interference pulse suppression
C = Outputs overcurrent and short-
circuit protected
Technical data MHT15-
Scanning distance
Type Order no.
MHT15-P3217V
MHT15-P3317V
MHT15-N3217V
MHT15-N3317V
1043805
1043806
1043803
1043804
Order information
100
10
1
02 04 60 08 001 120
% of scanning distance
(mm)
Operating
distance
Scanning
distance typ. max.
MHT15 axial
scr. 100 mm
1
2
3
MHT15V
0(mm) 20 40 60 80 100 120
Operating distance Scanning distance typ. max.
3
1
2
7510 65
10010 90
10
6515 50
3
Scanning distance on white, 90 % remission
2
Scanning distance on grey, 18 % remission
1
Scanning distance on black, 6 % remission
P3317V N3217V N3317V
DB_MH15V_en_KV2_1.indd 7 06.10.2009 14:51:59 Uhr