Datasheet

2 SICK 2008-09-11
IMF12 Inductive proximity sensors
Installation
notes
Installation in metal
The following notes are necessary to get proper operation.
IMF12-04B...
IMF12-08N...
A 6, B 12, C 12, D 0
A 12, B 24, C 24, D 12
Type
IMF12-02B...
IMF12-04N...
Metal-free zone [mm]
A 6, B 12, C 6, D 0
A 12, B 24, C 12, D 6
Reduction factor R
m
3 S
n
(C)
D
B
A
d
A
d = Outer diameter of the sensor
The following are reference values, which may vary from type to type:
St37 R
m
= 1
Stainless steel R
m
=
approx. 0.7
Aluminium R
m
=
approx. 0.3
Copper R
m
=
approx.
0.25
DB_IMF_en.indd 2DB_IMF_en.indd 2 05.12.2008 14:36:36 Uhr05.12.2008 14:36:36 Uhr