Datasheet

2010-06-17 SICK 59
Subject to change without notice
IME30
Technical specifications
IME30-
15NNO
ZC0S
15NNO
ZW2S
15NNS
ZC0S
15NNS
ZW2S
15NPO
ZC0S
15NPO
ZW2S
15NPS
ZC0S
15NPS
ZW2S
Sensing range S
n
15 mm
Electrical configuration
DC3-wire
Supply voltage V
s
DC 10 ... 30 V
Nominal voltage V
n
DC
Ripple U
pp
10 %
Voltage drop U
d
2 V
1)
Power consumption
10 mA
2)
Continuous current I
a
200 mA
Time delay before availability t
v
125 ms
Hysteresis H,
of s
r
5 ... 15 %
Repeatability R
2 % (U
b
and T
a
constant)
3)
Temperature drift,
of s
r
±
10 %
EMC According to EN 60947-5-2
Switching output
NPN
PNP
Output function
Normally closed
Normally open
Installation
Non-flush
Connection type
Connector, M12, 4-pin
Cable, PVC, 2 m
Enclosure rating
IP 67
4)
Max. switching frequency 500 Hz
Dimensions M30 x 1.5
5)
Short-circuit protection
6)
Reverse polarity protection
Power-up pulse suppression
Shock/vibration stress 30 g, 11 ms/10 ... 55 Hz, 1 mm
Ambient temperature T
a
–25
°
C ... +75
°
C
Housing material
Brass nickel-plated, plastic (PA6)
Tightening torque 100 Nm
1)
At I
a
max
2)
Without load
3)
Of s
r
4)
According to EN 60529
5)
Thread diameter x pitch (mm)
6)
(Pulsed)
Ordering information
Type Part Number
IME30-15NNOZC0S 1041026
IME30-15NNOZW2S 1041028
IME30-15NNSZC0S 1041022
IME30-15NNSZW2S 1041024
IME30-15NPOZC0S 1041018
IME30-15NPOZW2S 1041020
IME30-15NPSZC0S 1041014
IME30-15NPSZW2S 1041016
Reduction factor R
M
The following are reference values, which may vary from type to type:
St37 (Fe) 1
Stainless steel (V2A) Approx. 0.8
Aluminum (solid) Approx. 0.45
Copper (Cu) Approx. 0.4
Installation note
Mounting based on non-ferromagnetic materials
UL approval cULus Listed
Approvals
Protection class
DB_IME30_en.fm Seite 59 Montag, 28. Juni 2010 11:46 11