Datasheet

T-EASIC® FTS | SICK 8023179/2018-12- 07
Subject to change without notice
6
T-Easic
®
FTS FLOW SENSORS
Minimum immersion length
12 mm
Distance to pipe wall
10 mm
Electronics
Supply voltage
9 V DC ... 30 V DC
1)
Power consumption
< 2 W at 24 V DC (without load on the outputs)
Initialization time
≤ 5 s
≤ 10 s (IO-Link)
Protection class
III
Connection type
M12 round connector x 1, 4-pin
Output signal
2 x push-pull digital outputs for ow and temperature (Q2 can be selected as digital input)
Output current
< 100 mA
2)
Signal voltage HIGH
> Uv - 2 V
Signal voltage LOW
≤ 2 V
Inductive load
1 H
Capacitive load
100 nF (2.5 nF, IO-Link mode)
EMC
EN 61326-1, EN 61326-2-3
Digital input limit
HIGH voltage dependent on Uv
LOW voltage < 4.0 V
MTTF
> 200 years
1)
All connections are reverse polarity and overload protected. Q1 and Q2 are short-circuit protected.
2)
Per output.
Ambient data
Ambient operating temperature
–40 °C ... +70 °C
Ambient storage temperature
–40 °C ... +80 °C
Type code
Version
I Industrial
H Hygienic
Probe length
060 60 mm
100 100 mm
200 200 mm
Display
0 Without Display
1 With Display (OLED + 3 Status LED)
Electrical connection
4 M12 x 1, 4-pin
Electrical output
A 1 digital output + 1 digital input / output
FTS - F
Ordering information
Process pressure: 100 bar, 16 bar
Maximumow:≤ 150 cm/s, ≤ 300 cm/s
Process connection: Without process connection (adapter needed for installation)
Connection type: M12 round connector x 1, 4-pin
Probe length Housing material Display Type Part no.
60 mm VISTAL
®
/ polyester
l
FTS-I060F14A 1091146
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T